GENERATOR > INSPECTION |
| 1. INSPECT GENERATOR W/ VACUUM PUMP ASSEMBLY |
Mount the generator in a vise.
Insert the screwdriver to hold the generator rotor.
Hold the bolt and nut to the pulley.
![]() |
Set a dial indicator as shown in the illustration.
Turn the pulley and check the backlash between generator rotor and vacuum pump shaft.
| 2. INSPECT GENERATOR ROTOR ASSEMBLY |
Check the rotor for an open circuit.
![]() |
Using an ohmmeter, measure the resistance between the slip rings.
Check the rotor for a short circuit.
![]() |
Using an ohmmeter, measure the resistance between the each slip ring and rotor.
Check that the slip rings are not rough or scored.
If they are rough or scored, replace the rotor.
![]() |
Using vernier calipers, measure the slip ring diameter.
Inspect the bearing.
Check if the bearing is not rough or worn.
If necessary, replace the generator rotor.
| 3. INSPECT DRIVE END FRAME |
Check the stator for an open circuit.
![]() |
Using an ohmmeter, measure the resistance between the coil leads.
Check the stator for a short circuit.
![]() |
Using an ohmmeter, measure the resistance between the each coil lead and drive end frame assembly.
Inspect the bearing.
Check if the bearing is not rough or worn.
If necessary, replace the drive end frame assembly.
| 4. INSPECT BRUSH HOLDER |
![]() |
Using vernier calipers, measure the exposed brush length.
| 5. INSPECT GENERATOR HOLDER W/ RECTIFIER |
Check the positive terminal of the rectifier.
![]() |
Using an ohmmeter, connect one tester probe to the positive terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat step (1).
Check that one shows continuity and the other shows no continuity.
Check that there is continuity one way but no continuity the other way.
Check the negative terminal of the rectifier.
![]() |
Using an ohmmeter, connect one tester probe to each negative terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat step (1).
Check that there is continuity one way but no continuity the other way.
If the continuity is not as specified, replace the generator holder w/ rectifier.
| 6. INSPECT REGULATOR |
![]() |
Using an ohmmeter, check the continuity between terminals F and B.
![]() |
Using an ohmmeter, check the continuity between terminals F and E.