STARTING SYSTEM > INSPECTION |
| 1. INSPECT STARTER ASSEMBLY |
Perform the pull-in test.
![]() |
Disconnect the field coil lead wire from terminal C.
![]() |
Connect the battery to the magnetic switch as shown in the illustration. Check that the clutch pinion gear is extended.
Perform the hold test.
![]() |
Disconnect the negative (-) lead from terminal C while sustaining the above condition (a). Check that the pinion gear remains extended.
Check the return operation.
![]() |
Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.
Perform the operation test without any load.
![]() |
Connect the field coil lead wire to terminal C.
| Starter type | Torque |
| 2.0 kW | 5.9 N*m (60 kgf*cm, 52 in.*lbf) |
| 2.7 kW | 24 N*m (245 kgf*cm, 18 ft.*lbf) |
![]() |
Clamp the starter in a vise.
Connect the battery and ammeter to the starter as shown in the illustration.
Check that the ammeter indicates the specified current.
| Starter type | Current |
| 2.0 kW | 100 A or less |
| 2.7 kW | 180 A or less |