AIR OUTLET MODE CONTROL SWITCH > INSPECTION |
| 1. INSPECT AIR OUTLET MODE CONTROL SWITCH |
![]() |
Remove the air outlet mode control switch and disconnect the connector.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| 2 (L) - 3 (E) | A/C switch OFF | 10 kΩ or higher |
| 2 (L) - 4 (B) | A/C switch OFF | 10 kΩ or higher |
| 3 (E) - 4 (B) | Always | Below 1 Ω |
| 3 (E) - 2 (L) | A/C switch ON | Below 1 Ω |
| 2 (L - 4 (B) | A/C switch ON | Below 1 Ω |
| 5 (ILL+) - 6 ILL-) | Always | Below 1 Ω |
| Tester connection | Condition | Specified condition |
| 2 (L) - 3 (E) | A/C switch OFF | 10 kΩ or higher |
| 3 (E) - 4 (B) | A/C switch OFF | 10 kΩ or higher |
| 2 (L) - 4 (B) | Always | Below 1 Ω |
| 2 (L) - 3 (E) | A/C switch ON | Below 1 Ω |
| 3 (E) - 4 (B) | A/C switch ON | Below 1 Ω |
| 5 (ILL+) - 6 ILL-) | Always | Below 1 Ω |
Connect the positive battery terminal to terminal 5, and the negative battery terminal to terminal 6.