Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › FRONT BLOWER SWITCH

FRONT BLOWER SWITCH > INSPECTION

for Preparation Click here



1. INSPECT FRONT BLOWER SWITCH
  1. Remove the front front blower switch and disconnect the connector.



    E103716E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester connection
    Switch position
    Specified condition
    ALL - 8 (E)
    OFF
    10 kΩ or higher
    1 (C) - 8 (E)
    LO
    Below 1 Ω
    3 (M1) - 8 (E)
    M1
    Below 1 Ω
    2 (M2) - 8 (E)
    M2
    Below 1 Ω
    6 (H) - 8 (E)
    HI
    Below 1 Ω
    4 (P1) - 5 (P2)
    Always
    Below 1 Ω

    If the resistance value is not as specified, replace the front blower switch.

  1. Connect the positive battery to terminal 4 (P1), and the negative battery terminal to terminal 5 (P2).

    OK:
    The illumination light of the front blower switch comes on.

    If the resistance value is not as specified, replace the front blower switch.