Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › REAR BLOWER MOTOR (for Heater)

REAR BLOWER MOTOR (for Heater) > INSPECTION

for Preparation Click here



1. INSPECT REAR BLOWER MOTOR


    E103719E01
  1. Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 2, then check that the motor operates smoothly.

    OK:
    The motor operates smoothly.

    If the operation is not as specified, replace the rear blower motor.

  1. Measure the current according to the value(s) in the table below.

    Standard current:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Blower motor operate
    Below 1.8 A

    If the current value is not as specified, replace the rear blower motor.