Home
›
BODY ELECTRICAL
›
PARK ASSIST / MONITORING
›
NO. 1 ULTRASONIC SENSOR
NO. 1 ULTRASONIC SENSOR > INSPECTION
1. INSPECT NO.1 ULTRASONIC SENSOR
Measure the resistance according to the value(s) in the table below.
Resistance:
Tester connection
Condition
Specified condition
1 - 2
Always
900 +- 300 kΩ
If the result is not as specified, replace No.1 ultrasonic sensor.