Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 2TR-FE COOLING

2TR-FE COOLING > SERVICE DATA



No. 1 cooling fan motor
Standard current
4 to 23 A
(when the A/C switch is on (MAX COOL and the magnet clutch is operating))
Standard current
17 to 23 A (20°C (68°F)) at 12V
(when the battery is connected to the fan motor connector)
Standard current
8 to 24 A
(when the water temperature sensor connector is disconnected)
No. 2 cooling fan motor
Standard current
4 to 23A
(when the A/C switch is on (MAX COOL and the magnet clutch is operating))
Standard current
17 to 23 A (20°C (68°F)) at 12V
(when the battery is connected to the fan motor connector)
(when the water temperature sensor connector is disconnected)
Standard current
8 to 24 A
(when the water temperature sensor connector is disconnected)
Water inlet with thermostat
Valve opening temperature
80 to 84°C (176 to 183°F)
Valve lift
8.0 mm (0.315 in.) or more at 95°C (203°F)
Engine coolant temperature sensor
Resistance at approx. 20°C (68°F): 2.32 to 2.59 Ω
Resistance at approx. 80°C (176°F): 0.310 to 0.326 Ω
Cooling fan relay
Standard resistance: 10 MΩ or higher
Standard resistance: Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
Cooling fan ECU
Standard voltage
9 to 14 V
(when turn the engine switch on (IG))
Thermostat

Valve opening temperature
80 to 84°C (176 to 183°F)
Valve lift
at 95°C (203°F): 10 mm (0.394 in.) or more
Radiator cap sub-assembly

Standard opening pressure
93.3 to 122.7 kPa (095 to 1.25 kgf/cm2, 13.5 to 17.8 psi)