2014-2019 Hiace · Service Manual TRANSMISSION

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Oct 2014


INSPECT SHIFT LOCK CONTROL ECU

HINT:
Do not disconnect the shift lock control unit assembly connector.

  1. C297187E01
    Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    5 (KLS+) - 1 (E)
    Ignition switch ACC and shift lever in P
    Below 1 V
    Ignition switch ACC and shift lever not in P
    11 to 14 V
    6 (ACC) - 1 (E)
    Ignition switch ACC
    11 to 14 V
    Ignition switch off
    Below 1 V
    4 (STP) - 1 (E)
    Brake pedal depressed
    11 to 14 V
    Brake pedal released
    Below 1 V
    8 (IG) - 1 (E)
    Ignition switch ON
    11 to 14 V
    Ignition switch off
    Below 1 V
    10 (SLS-) - 1 (E)
    Ignition switch ON, brake pedal depressed and shift lever in P
    Below 2.5 V
    Ignition switch ON, brake pedal released and shift lever in P
    11 to 14 V

    Text in IllustrationĀ 
    *a
    Component with harness connected
    (Shift Lock Control ECU)
    If the result is not as specified, replace the shift lock control ECU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (E) - Body ground
    Always
    Below 1 Ī©

    If the result is not as specified, replace the shift lock control ECU.

← INSTALLATION (from Jan 2017)COMPONENTS (from Oct 2014) →