2014-2019 Hiace · Service Manual TRANSMISSION

INSPECTION

Inspection · Vehicles built from Jan 2015


INSPECT TRANSMISSION REVOLUTION SENSOR (NT)

  1. Connect the battery to the transmission revolution sensor (NT) as shown in the illustration.

    C297974E05

    Text in Illustration 
    *1
    Transmission Revolution Sensor (NT)
    *2
    Battery
    *a
    Component without harness connected
    (Transmission Revolution Sensor (NT))
    *b
    Ammeter
    *c
    Magnet
    *d
    5 mm (0.197 in.) or less

  1. Wave a magnetic object left and right in front of the transmission revolution sensor (NT) tip (5 mm (0.197 in.) or less) to change the high/low signals while measuring the current.

    NOTICE:
    Make sure to wave the magnetic object during the inspection. The current will not change without waving the magnetic object as indicated by the arrow in the illustration.

  1. Measure the current according to the value(s) in the table below.

    Standard Current:
    Tester Connection
    Condition
    Specified Condition
    1 (NTO) - 2 (NTB)
    Low signal
    4 to 8 mA
    High signal
    12 to 16 mA

    If the result is not as specified, replace the transmission revolution sensor (NT).


INSPECT TRANSMISSION REVOLUTION SENSOR (SP2)

  1. Connect the battery to the transmission revolution sensor (SP2) as shown in the illustration.

    C297974E06

    Text in Illustration 
    *1
    Transmission Revolution Sensor (SP2)
    *2
    Battery
    *a
    Component without harness connected
    (Transmission Revolution Sensor (SP2))
    *b
    Ammeter
    *c
    Magnet
    *d
    5 mm (0.197 in.) or less

  1. Wave a magnetic object left and right in front of the transmission revolution sensor (SP2) tip (5 mm (0.197 in.) or less) to change the high/low signals while measuring the current.

    NOTICE:
    Make sure to wave the magnetic object during the inspection. The current will not change without waving the magnetic object as indicated by the arrow in the illustration.

  1. Measure the current according to the value(s) in the table below.

    Standard Current:
    Tester Connection
    Condition
    Specified Condition
    1 (SP2O) - 2 (SP2B)
    Low signal
    4 to 8 mA
    High signal
    12 to 16 mA

    If the result is not as specified, replace the transmission revolution sensor (SP2).

← REMOVAL (from Jan 2015)INSTALLATION (from Jan 2015) →