2014-2019 Hiace · Service Manual RESTRAINTS

B1805/52 Short in Front Passenger Side Squib Circuit

Diagnostic trouble codes · Vehicles built Apr 2016 – Dec 2016

Also covers:

Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017

DESCRIPTION

The front passenger side squib circuit consists of the center airbag sensor assembly and the front passenger airbag assembly.
The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the front passenger side squib circuit.
DTC No.
DTC Detection Condition
Trouble Area
B1805/52
  1. The center airbag sensor assembly receives a line short circuit signal 5 times in the front passenger side squib circuit during primary check.
  2. Front passenger side squib malfunction
  3. Center airbag sensor assembly malfunction
  1. Engine room main wire
  2. Instrument panel wire
  3. Instrument panel wire No.3
  4. Front passenger airbag assembly (Front passenger side squib)
  5. Center airbag sensor assembly
B1806/52
  1. The center airbag sensor assembly receives an open circuit signal in the front passenger side squib circuit for 2 seconds.
  2. Front passenger side squib malfunction
  3. Center airbag sensor assembly malfunction
  1. Engine room main wire
  2. Instrument panel wire
  3. Instrument panel wire No.3
  4. Front passenger airbag assembly (Front passenger side squib)
  5. Center airbag sensor assembly
B1807/52
  1. The center airbag sensor assembly receives a short circuit to ground signal in the front passenger side squib circuit for 0.5 seconds.
  2. Front passenger side squib malfunction
  3. Center airbag sensor assembly malfunction
  1. Engine room main wire
  2. Instrument panel wire
  3. Instrument panel wire No.3
  4. Front passenger airbag assembly (Front passenger side squib)
  5. Center airbag sensor assembly
B1808/52
  1. The center airbag sensor assembly receives a short circuit to B+ signal in the front passenger side squib circuit for 0.5 seconds.
  2. Front passenger side squib malfunction
  3. Center airbag sensor assembly malfunction
  1. Engine room main wire
  2. Instrument panel wire
  3. Instrument panel wire No.3
  4. Front passenger airbag assembly (Front passenger side squib)
  5. Center airbag sensor assembly

WIRING DIAGRAM

C111991E01

INSPECTION PROCEDURE

NOTICE:
After replacing the airbag ECU assembly, refer to initialization (Click here).

HINT:
To perform the simulation method, select the "check mode" (signal check) with the intelligent tester (Click here), and then wiggle each connector of the airbag system or drive the vehicle on a city or rough road (Click here).


1. CHECK FRONT PASSENGER AIRBAG ASSEMBLY (FRONT PASSENGER SIDE SQUIB)

  1. C111992E01
    Turn the ignition switch to the LOCK position.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect the connector from the front passenger airbag assembly.

  1. Connect the white wire side of SST (resistance 2.1 Ω) to connector "G".

    CAUTION:
    Never connect a tester to the front passenger airbag assembly (Front passenger side squib) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert the SST into the terminals of the connector.
    2. Insert the SST straight into the terminals of the connector.

SST
09843-18060  
  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Clear the DTCs stored in memory (Click here).

  1. Turn the ignition switch to the LOCK position.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Check the DTCs (Click here).

    OK:
    DTC B1805, B1806, B1807, B1808 or 52 is not output.

    HINT:
    Codes other than DTC B1805, B1806, B1807, B1808 and 52 may be output at this time, but they are not related to this check.



OK
REPLACE FRONT PASSENGER AIRBAG ASSEMBLY
NG


2. CHECK CONNECTOR
  1. Turn the ignition switch to the LOCK position.

  1. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

  1. Disconnect the SST from connector "G".

  1. Check that the instrument panel wire No.3 connector (on the front passenger airbag assembly side) is not damaged.

    OK:
    The lock button is not disengaged, or the claw of the lock is not deformed or damaged.



NG
REPAIR OR REPLACE INSTRUMENT PANEL WIRE NO.3
OK


3. CHECK FRONT PASSENGER SIDE SQUIB CIRCUIT

  1. C111993E01
    Disconnect the connectors from the center airbag sensor assembly.

  1. Check for short to B+ in the circuit.

    1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

    2. Turn the ignition switch to the ON position.

    3. Measure the voltage according to the value(s) in the table below.

      Voltage:
      Tester connection
      Switch Condition
      Specified condition
      J1-1 (P+) - Body ground
      Ignition switch ON
      Below 1 V
      J1-2 (P-) - Body ground
      Ignition switch ON
      Below 1 V

  1. Check for open in the circuit.

    1. Turn the ignition switch to the LOCK position.

    2. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

    3. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      J1-1 (P+) - J1-2 (P-)
      Always
      Below 1 Ω

  1. Check for short to ground in the circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      J1-1 (P+) - Body ground
      Always
      1 MΩ or higher
      J1-2 (P-) - Body ground
      Always
      1 MΩ or higher

  1. Check for short in the circuit.

    1. Release the activation prevention mechanism built into connector "B" (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      J1-1 (P+) - J1-2 (P-)
      Always
      1 MΩ or higher



NG
Go to step 5
OK


4. CHECK CENTER AIRBAG SENSOR ASSEMBLY

  1. C111994E01
    Connect the connectors to the front passenger airbag assembly and the center airbag sensor assembly.

  1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Clear the DTCs stored in memory (Click here).

  1. Turn the ignition switch to the LOCK position.

  1. Turn the ignition switch to the ON position, and wait for at least 60 seconds.

  1. Check the DTCs (Click here).

    OK:
    DTC B1805, B1806, B1807, B1808 or 52 is not output.

    HINT:
    Codes other than DTC B1805, B1806, B1807, B1808 and 52 may be output at this time, but they are not related to this check.



NG
REPLACE CENTER AIRBAG SENSOR ASSEMBLY
OK

USE SIMULATION METHOD TO CHECK

5. CHECK ENGINE ROOM MAIN WIRE

  1. C111995E01
    Restore the released activation prevention mechanism of connector "B" to the original condition.

  1. Disconnect the engine room main wire connector from the instrument panel wire.

  1. Check for short to B+ in the circuit.

    1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

    2. Turn the ignition switch to the ON position.

    3. Measure the voltage according to the value(s) in the table below.

      Voltage:
      Tester connection
      Switch Condition
      Specified condition
      HB3-2 (P+) -
      Body ground
      Ignition switch ON
      Below 1 V
      HB3-4 (P-) -
      Body ground
      Ignition switch ON
      Below 1 V

  1. Check for open in the circuit.

    1. Turn the ignition switch to the LOCK position.

    2. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

    3. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      HB3-2 (P+) - HB3-4 (P-)
      Always
      Below 1 Ω

  1. Check for short to ground in the circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      HB3-2 (P+) -
      Body ground
      Always
      1 MΩ or higher
      HB3-4 (P-) -
      Body ground
      Always
      1 MΩ or higher

  1. Check for short to ground in the circuit.

    1. Release the activation prevention mechanism built into connector "B" (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      HB3-2 (P+) - HB3-4 (P-)
      Always
      1 MΩ or higher



NG
REPAIR OR REPLACE ENGINE ROOM MAIN WIRE
OK


6. CHECK INSTRUMENT PANEL WIRE

  1. C111996E01
    Disconnect the instrument panel wire connector from the instrument panel wire No.3.

  1. Check for short to B+ in the circuit.

    1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

    2. Turn the ignition switch to the ON position.

    3. Measure the voltage according to the value(s) in the table below.

      Voltage:
      Tester connection
      Switch Condition
      Specified condition
      HJ1-2 (P+) -
      Body ground
      Ignition switch ON
      Below 1 V
      HJ1-1 (P-) -
      Body ground
      Ignition switch ON
      Below 1 V

  1. Check for open in the circuit.

    1. Turn the ignition switch to the LOCK position.

    2. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

    3. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      HJ1-2 (P+) - HJ1-1 (P-)
      Always
      Below 1 Ω

  1. Check for short to ground in the circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      HJ1-2 (P+) -
      Body ground
      Always
      1 MΩ or higher
      HJ1-1 (P-) -
      Body ground
      Always
      1 MΩ or higher

  1. Check for short in the circuit.

    1. Release the activation prevention mechanism built into connector "D" (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      HJ1-2 (P+) - HJ1-1 (P-)
      Always
      1 MΩ or higher



NG
REPAIR OR REPLACE INSTRUMENT PANEL WIRE
OK


7. CHECK INSTRUMENT PANEL WIRE NO.3

  1. C111997E01
    Check for short to B+ in the circuit.
    1. Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.

    2. Turn the ignition switch to the ON position.

    3. Measure the voltage according to the value(s) in the table below.

      Voltage:
      Tester connection
      Switch Condition
      Specified condition
      J1-1 (P+) - Body ground
      Ignition switch ON
      Below 1 V
      J1-2 (P-) - Body ground
      Ignition switch ON
      Below 1 V

  1. Check for open in the circuit.

    1. Turn the ignition switch to the LOCK position.

    2. Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.

    3. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      J1-1 (P+) - J1-2 (P-)
      Always
      Below 1 Ω

  1. Check for short to ground in the circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      J1-1 (P+) - Body ground
      Always
      1 MΩ or higher
      J1-2 (P-) - Body ground
      Always
      1 MΩ or higher

  1. Check for short in the circuit.

    1. Release the activation prevention mechanism built into connector "F" (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Resistance:
      Tester connection
      Condition
      Specified condition
      J1-1 (P+) - J1-2 (P-)
      Always
      1 MΩ or higher



NG
REPAIR OR REPLACE INSTRUMENT PANEL WIRE NO.3
OK

USE SIMULATION METHOD TO CHECK


← B1805/52 Short in Front Passenger Side Squib Circuit (+ B1806/52, B1807/52, B1808/52) (Jan 2015 – Mar 2016)B1805/52 Short in Front Passenger Side Squib Circuit (+ B1806/52, B1807/52, B1808/52) (from Jan 2017) →