ON-VEHICLE INSPECTION
Inspection · Vehicles built from Oct 2014
| CHECK BATTERY CONDITION |
- CAUTION:
- If the battery is weak or if the engine is difficult to start, perform the following procedures.
Check the battery for damage and deformation. If severe damage, deformation, or leakage is found, replace the battery.
Check the electrolyte level of each cell.
For maintenance-free batteries:
- If the electrolyte level is below the lower line, replace the battery.
- If the electrolyte level is above the lower line, check the battery voltage when cranking the engine.
- If the voltage is less than 9.6 V, recharge or replace the battery.
- HINT:
- Before checking the battery voltage, turn off all electrical systems (headlights, blower motor, rear defogger, etc.).
- If the electrolyte level is below the lower line, replace the battery.
For non-maintenance-free batteries:
- If the electrolyte level is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte gravity.
- Standard gravity:
- 1.25 to 1.29 at 20°C (68°F)
- HINT:
- Before checking the battery voltage, turn off all electrical systems (headlights, blower motor, rear defogger, etc.).
- If the electrolyte level is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte gravity.
| CHECK BATTERY TERMINAL AND FUSE |
Check that the battery terminals are not loose or corroded.
If the terminals are corroded, clean the terminals.
Measure the resistance of the ALT fuse and ALT-S fuse.
- Standard resistance:
- Below 1 Ω
| CHECK V-RIBBED BELT |
Check the belt for wear, cracks and other signs of damage.

If any of the following defects is found, replace the drive belt.- The belt is worn and wire is exposed.
- The cracks reach the wire in more than one place.
- The belt has chunks missing from the ribs.
- The belt is worn and wire is exposed.
Check that the belt fits properly in the ribbed grooves.

- HINT:
- Confirm by hand that the belt has not slipped out of the grooves on the bottom of the pulley.
| VISUALLY CHECK GENERATOR WIRING |
Check that the wiring is in good condition.
| LISTEN FOR ABNORMAL NOISE FROM GENERATOR |
Check that the generator does not emit any abnormal noise while the engine is running.
| CHECK CHARGE WARNING LIGHT CIRCUIT |
Turn the ignition switch to the ON position. Check that the charge warning light comes on.
Start the engine and check that the light goes off. If the light does not operate as specified, troubleshoot the charge warning light circuit.
| CHECK CHARGING CIRCUIT WITHOUT LOAD |
Connect a voltmeter and ammeter to the charging circuit as follows:

- HINT:
- If a battery/generator tester is available, connect the tester to the charging circuit according to the manufacturer's instructions.
Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.
Connect the positive (+) lead of the ammeter to terminal B of the generator.
Connect the positive (+) lead of the voltmeter to the positive (+) terminal of the battery.
Ground the negative (-) lead of the voltmeter.
Check the charging circuit.
Keep the engine speed at 2,000 rpm. Check the reading on the ammeter and voltmeter.
- Standard current:
- 10 A or less
- Standard voltage:
- 13.2 to 14.8 V
- HINT:
- If the battery is not fully charged, the ammeter reading may be more than the standard current.
| CHECK CHARGING CIRCUIT WITH LOAD |
With the engine running at 2,000 rpm, turn on the high beam headlights and turn the heater blower switch to the HI position.
Check the reading on the ammeter.
- Standard current:
- 30 A or more
- HINT:
- If the battery is fully charged, the ammeter reading may be less than the standard current.
- In this case, increase electrical load by operating electrical equipment such as the wiper motor and rear window defogger. Then, recheck the reading on the ammeter.
- If the battery is fully charged, the ammeter reading may be less than the standard current.
| MATRIX FOR EACH PROBLEM SYMPTOM |
Confirm problem symptom.
Confirm the problem symptom and perform inspection by following the corresponding chart.
Result: Result
Proceed to
Problem in charging system (battery is dead and charging light comes on)
Go to step (c)
Belt noise and excessive slip
Go to step (g)
Noise from generator
Go to next step
Perform the functional check of the generator with clutch pulley.
Check the function with the pulley installed in the vehicle:
- Visually check that the rotor in the generator operates with the engine started.
- Visually check that the rotor in the generator operates with the engine started.
Check the function with the pulley removed from the vehicle:
- Remove the generator pulley cap. Using SST, fix the generator rotor.
- Turn the generator with clutch pulley clockwise and check that it does not operate.
- SST
- 09820-63020
- HINT:
- Be sure to replace the generator pulley cap with a new one because it cannot be reused.
Result: Result
Proceed to
NG
Replace generator with clutch pulley
OK
Repair or replace generator assembly
- Remove the generator pulley cap. Using SST, fix the generator rotor.
Check the V belt for wear.
Check the V belt for wear.
Result: Result
Proceed to
NG
Replace fan and generator V belt
OK
Go to next step
Check the generator with clutch pulley for wear.
Check the generator with clutch pulley groove for wear or other defects.
Result: Result
Proceed to
NG
Replace generator with clutch pulley
OK
Go to next step
Check the operation of the one-way clutch.
Check that the generator with clutch pulley (outer ring) turns counterclockwise.
Result: Result
Proceed to
NG
Replace generator with clutch pulley
OK
Go to next step
Check looseness of the generator with clutch pulley.
Start the engine and check looseness of the generator with clutch pulley.
Result: Result
Proceed to
NG
Tighten generator with clutch pulley to the specified torque {110 N*m (1,125 kgf*cm, 81 ft.*lbf)}
OK
Check other pulleys
Perform the functional check of the generator with clutch pulley.
Remove the generator pulley cap. Using SST, fix the generator rotor.
- SST
- 09820-63020
- HINT:
- Be sure to replace the generator pulley cap with a new one because it cannot be reused.
Turn the generator with clutch pulley counterclockwise and check that it locks.
Result: Result
Proceed to
NG
Replace generator with clutch pulley
OK
Go to next step
Check for noise while the generator with clutch pulley is operating.
Perform a driving test and check if noise occurs when decelerating.
Result: Result
Proceed to
NG
Replace generator with clutch pulley
OK
Repair or replace generator assembly