2014-2019 Hiace · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Oct 2014


INSPECT CRANK POSITION SENSOR
  1. Resistance inspection.

    1. Using an ohmmeter, measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Temperature
      Resistance
      at -10°C (14°F) to 50°C (122°F)
      19 to 32 Ω
      at 50°C (122°F) to 100°C (212°F)
      24 to 37 Ω

      NOTICE:
      "Cold" and "Hot" in the following sentence express the temperature of the sensor itself. "Cold" is from -10°C (14°F) to 50°C (122°F) and "Hot" is from 50°C (122°F) to 100°C (212°F).

← REMOVAL (from Oct 2014)INSTALLATION (from Oct 2014) →