INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT MASS AIR FLOW METER |
Check the output voltage.
Apply battery voltage across terminals 1 (+B) and 2 (E2G).

Text in Illustration *a
Air
- NOTICE:
- While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG) and the negative (-) tester probe to terminal 2 (E2G).
Blow air into the mass air flow meter and check that the voltage fluctuates.
If the voltage does not fluctuate, replace the mass air flow meter.
Check the resistance.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
4 (THA) - 5 (E2)
-20°C (-4°F)
12.5 to 16.9 kΩ
4 (THA) - 5 (E2)
20°C (68°F)
2.19 to 2.67 kΩ
4 (THA) - 5 (E2)
60°C (140°F)
0.50 to 0.68 kΩ
If the result is not as specified, replace the mass air flow meter.Text in Illustration *a
Component without harness connected
(Mass Air Flow Meter)
*b
Resistance
*c
Temperature
*d
Acceptable Range