ON-VEHICLE INSPECTION
Inspection · Vehicles built from Jan 2017
| INSPECT DIESEL TURBO PRESSURE SENSOR |
Inspect the power source voltage.
Disconnect the diesel turbo pressure sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.

- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
3 (VC) - 1 (E2)
Ignition switch ON
4.75 to 5.25 V
Text in Illustration *a
Front view of wire harness connector
(to Diesel Turbo Pressure Sensor)
Turn the ignition switch off.
Connect the diesel turbo pressure sensor connector.
Clear the DTCs.
Inspect the diesel turbo pressure sensor.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Atmosphere Pressure and MAP.
Disconnect the vacuum hose from the diesel turbo pressure sensor.
Using SST, apply pressure to the diesel turbo pressure sensor.

- SST
- 09992-00242
Text in Illustration *a
Vacuum Pump
Using a vacuum pump, apply vacuum to the diesel turbo pressure sensor.
Read the value.
- OK:
Condition
MAP Value
No pressure applied
Same as atmospheric pressure
Pressure applied
Indicates pressure
Vacuum applied
Indicates vacuum