INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT COOLING FAN RELAY |
Check the resistance.

Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
3 - 5
10 kΩ or higher
3 - 5
Below 1 Ω (when battery voltage is applied between terminals 1 and 2)
| INSPECT COOLING FAN MOTOR |
Check that the motor turns smoothly when the battery is connected to the fan motor connector.
Using an ammeter, measure the current while the motor is turning.
- Standard:
- 17 to 23 A (20°C (68°F)) at 12 V
| ENGINE COOLANT TEMPERATURE SENSOR |
Partially soak the sensor in the water and warm up the water.


Measure the resistance between the terminals.
- Standard resistance:
Condition
Specified Condition
Approx. 20°C (68°F)
2.32 to 2.59 kΩ
Approx. 80°C (176°F)
0.310 to 0.326 kΩ
- NOTICE:
- When checking the sensor in the water, keep the terminals dry. After the check, wipe the sensor dry.