2014-2019 Hiace · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from Oct 2014

INTAKE MANIFOLD (w/o DPF) 
Engine Condition
VSV Condition
Specified Condition
Idling
ON
Approx. 35 kPa (263 mmHg, 10.3 in.Hg)
3000 rpm or higher
OFF
0 kPa (0 mmHg, 0 in.Hg)
MANIFOLD ABSOLUTE PRESSURE SENSOR 
Tester Connection
Condition
Specified Condition
D51-3 (VC) - D51-1 (E)
Ignition switch ON
4.75 to 5.25 V
D51-2 (PIM) - D51-1 (E)
Ignition switch ON
3.0 to 5.0 V
TURBOCHARGER 
Item
Condition
Specified Condition
Turbocharger pressure (w/ DPF)
Engine speed (approximately 4600 rpm)
5 to 35 kPa (0.05 to 0.35 kgf*cm2, 0.72 to 5.0 psi)
Turbocharger pressure (w/o DPF)
Engine speed (approximately 4450 rpm)
10 to 40 kPa (0.10 to 0.41 kgf*cm2, 1.4 to 5.8 psi)
Axial play of turbine shaft
Maximum axial play
0.11 mm (0.00433 in.)
← TORQUE SPECIFICATIONS (from Jan 2015)TORQUE SPECIFICATIONS (from Oct 2014) →