RELAY
Item
|
Tester Connection
|
Condition
|
Specified Condition
|
No. 2 integration relay (HD-LP NO. 1)
|
d-2 - 12D-3
|
Battery voltage not applied to terminals d-2 and 12D-4
|
10 kΩ or higher
|
Battery voltage applied to terminals d-2 and 12D-4
|
Below 1 Ω
|
No. 2 integration relay (DIM NO. 1)
|
12A-1 - 12C-2
|
Battery voltage not applied to terminals 12C-3 and 12C-1
|
10 kΩ or higher
|
Battery voltage applied to terminals 12C-3 and 12C-1
|
Below 1 Ω
|
No. 2 integration relay (HD-LP NO. 2)
|
c-2 - 12B-9
|
Battery voltage not applied to terminals c-2 and 12B-10
|
10 kΩ or higher
|
Battery voltage applied to terminals c-2 and 12B-10
|
Below 1 Ω
|
No. 2 integration relay (DIM NO. 2)
|
12A-1 - 12B-12
|
Battery voltage not applied to terminals 12B-8 and 12B-11
|
10 kΩ or higher
|
Battery voltage applied to terminals 12B-8 and 12B-11
|
Below 1 Ω
|
No. 2 integration relay (IG2)
|
12A-1 - 12D-1
|
Battery voltage not applied to terminals 12D-2 and 12E-4
|
10 kΩ or higher
|
Battery voltage applied to terminals 12D-2 and 12E-4
|
Below 1 Ω
|
No. 2 integration relay (DRL)
|
12A-1 - 12D-6
|
Battery voltage not applied to terminals 12E-12 and 12D-7
|
10 kΩ or higher
|
Battery voltage applied to terminals 12E-12 and 12D-7
|
Below 1 Ω
|
No. 2 integration relay (ACC)
|
12E-7 - 12E-9
|
Battery voltage not applied to terminals 12E-8 and 12E-4
|
10 kΩ or higher
|
Battery voltage applied to terminals 12E-8 and 12E-4
|
Below 1 Ω
|
No. 2 integration relay (100V)
|
12A-1 - 12E-3
|
Battery voltage not applied to terminals 12E-1 and 12E-4
|
10 kΩ or higher
|
Battery voltage applied to terminals 12E-1 and 12E-4
|
Below 1 Ω
|
No. 2 integration relay (FR FOG)
|
12B-3 - 12B-1
|
Battery voltage not applied to terminals 12B-6 and 12C-4
|
10 kΩ or higher
|
Battery voltage applied to terminals 12B-6 and 12C-4
|
Below 1 Ω
|
No. 2 integration relay (DOME CUT)
|
12C-7 - 12C-6
|
Battery voltage not applied to terminals 12C-8 and 12C-5
|
10 kΩ or higher
|
Battery voltage applied to terminals 12C-8 and 12C-5
|
Below 1 Ω
|