2014-2019 Hiace · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from Jan 2017

THERMOSTAT 
Standard Valve Opening Temperature
Standard Valve Lift
80 to 84°C (176 to 183°F)
10 mm (0.394 in.) or more at 95°C (203°F)
COOLING FAN SWITCH 
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
2.32 to 2.59 kΩ
80°C (176°F)
0.310 to 0.326 kΩ
RADIATOR CAP 
Item
Specified Condition
Standard Valve
(for brand-new cap)
93 to 123 kPa (1.0 to 1.3kgf/cm2, 13.5 to 18 psi)
Minimum Standard Valve
(for used cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)
← TORQUE SPECIFICATIONS (from Oct 2014)TORQUE SPECIFICATIONS (from Jan 2017) →