INSPECTION
Inspection · Vehicles built Oct 2014 – Dec 2014
| INSPECT SHIFT SOLENOID VALVE SLT |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve SLT)
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 2
| INSPECT SHIFT SOLENOID VALVE SL |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Shift solenoid valve SL connector terminal - Shift solenoid valve SL body
20°C (68°F)
11 to 15 Ω
Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve SL)
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) → Shift solenoid valve SL connector
- Battery negative (-) → Shift solenoid valve SL body
Valve moves and makes an operating noise
- Battery positive (+) → Shift solenoid valve SL connector
| INSPECT SHIFT SOLENOID VALVE S1 AND S2 |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Shift solenoid valve connector terminal - Shift solenoid valve body
20°C (68°F)
11 to 15 Ω
Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve S1 and S2)
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) → Shift solenoid valve connector
- Battery negative (-) → Shift solenoid valve body
Valve moves and makes an operating noise
- Battery positive (+) → Shift solenoid valve connector