2014-2019 Hiace · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built from Jan 2017

INTAKE SYSTEM 
Turbocharger pressure
Standard pressure (Gauge Pressure)
11.4 to 47.2 kPa (0.1 to 0.5 kgf/cm2, 1.7 to 6.8 psi)
INTAKE MANIFOLD 
Item
Tester Connection
Condition
Specified Condition
Vacuum switching valve (for Swirl Control Valve)
1 - 2
20°C (68°F)
33 to 39 Ω
1 - Body ground
10 kΩ or higher
2 - Body ground
10 kΩ or higher
TURBOCHARGER 
Axial play of turbine shaft
Standard
0.11 mm (0.00433 in.)
Turbocharger nozzle vane control actuator
Condition 20°C (68°F)
1 to 100 Ω