Certification ECU Communication Stop Mode
Circuit diagnosis · Vehicles built Jan 2015 – Mar 2016
Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017
DESCRIPTION
| Detection Item |
Symptom |
Trouble Area |
| Certification ECU Communication Stop Mode |
Either condition is met:
|
|
- For vehicles with a smart entry and start system.
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Before replacing the certification ECU (smart key ECU assembly), refer to the smart entry and start system (Click here).
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
- Before replacing the certification ECU (smart key ECU assembly), refer to the smart entry and start system (Click here).
- HINT:
- Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.
- CAUTION:
- For vehicles with an airbag system:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
| NEXT | |
| 2. CHECK FOR OPEN IN CAN BUS WIRE (CERTIFICATION ECU CAN BRANCH WIRE) |
Disconnect the certification ECU (smart key ECU assembly) connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
B76-40 (CANH) - B76-18 (CANL)
Ignition switch off
54 to 69 Ω
Text in Illustration *a
Front view of wire harness connector
(to Certification ECU [Smart Key ECU Assembly])
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - BATTERY AND BODY GROUND) |
Connect the cable to the negative (-) battery terminal.

- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
Disconnect the certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
B75-10 (E) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
B75-1 (+B) - Body ground
Always
11 to 14 V
| *a |
Front view of wire harness connector (to Certification ECU [Smart Key ECU Assembly]) |
|
|
||||
| OK | ||
| ||