INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT SHIFT LOCK CONTROL ECU (w/o Smart Entry and Start System) |
- HINT:
- Do not disconnect the shift lock control unit assembly connector.
Measure the voltage according to the value(s) in the table below.

- Standard Voltage:
Tester Connection
Condition
Specified Condition
5 (KLS+) - 1 (E)
Ignition switch ACC and shift lever in P
Below 1 V
Ignition switch ACC and shift lever not in P
11 to 14 V
6 (ACC) - 1 (E)
Ignition switch ACC
11 to 14 V
Ignition switch off
Below 1 V
4 (STP) - 1 (E)
Brake pedal depressed
11 to 14 V
Brake pedal released
Below 1 V
8 (IG) - 1 (E)
Ignition switch ON
11 to 14 V
Ignition switch off
Below 1 V
10 (SLS-) - 1 (E)
Ignition switch ON, brake pedal depressed and shift lever in P
Below 2.5 V
Ignition switch ON, brake pedal released and shift lever in P
11 to 14 V
If the result is not as specified, replace the shift lock control ECU.Text in Illustration *a
Component with harness connected
(Shift Lock Control ECU)
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (E) - Body ground
Always
Below 1 Ω
| INSPECT SHIFT LOCK CONTROL ECU (w/ Smart Entry and Start System) |
- HINT:
- Do not disconnect the shift lock control unit assembly connector.
Measure the voltage according to the value(s) in the table below.

- Standard Voltage:
Tester Connection
Condition
Specified Condition
6 (STP) - 3 (E)
Brake pedal depressed
11 to 14 V
Brake pedal released
Below 1 V
12 (IG) - 3 (E)
Engine switch on (IG)
11 to 14 V
Engine switch off
Below 1 V
14 (SLS-) - 3 (E)
Engine switch on (IG), brake pedal depressed and shift lever in P
Below 2.5 V
Engine switch on (IG), brake pedal released and shift lever in P
11 to 14 V
If the result is not as specified, replace the shift lock control ECU.Text in Illustration *a
Component with harness connected
(Shift Lock Control ECU)
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (E) - Body ground
Always
Below 1 Ω
| INSPECT SHIFT LOCK SOLENOID |
Disconnect the shift lock solenoid connector from the shift lock control ECU.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
4 (P) - 3 (E2)
Shift lever in P
10 kΩ or higher
Shift lever not in P
Below 1 Ω
1 (SLS+) - 2 (SLS-)
Always
112 Ω
If the result is not as specified, replace the shift lock control unit assembly.Text in Illustration *a
Component without harness connected
(Shift Lock Solenoid)
| INSPECT TRANSMISSION CONTROL SWITCH |
Disconnect the transmission control switch connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (NSSD) - 2 (ATS)
Shift lever in 3
Below 1 Ω
Shift lever not in 3
10 kΩ or higher
1 (NSSD) - 3 (ATD)
Shift lever in D
Below 1 Ω
Shift lever not in D
10 kΩ or higher
If the result is not as specified, replace the shift lock control unit assembly.Text in Illustration *a
Component without harness connected
(Transmission Control Switch)