Home › Vehicle Exterior › BODY PANEL › FRONT BODY PILLAR (for Standard Roof) › from 2019.06
BM35X0E _01 Vehicle Exterior _080418 BODY PANEL _0389998 FRONT BODY PILLAR(for Standard Roof) F

BODY PANEL  FRONT BODY PILLAR(for Standard Roof)  CUT AND JOIN REPLACEMENT SECTIONS (PATTERN 2)  


K151884

With the cowl top side upper panel assembly, cowl top side panel assembly and roof panel assembly removed.


REMOVAL


Symbol Meaning
K108818

Remove Weld Points
K108819

Remove Weld Points
K108820

Remove Weld Points
K108827

Cut and Join Location

a.

Do not butt weld or heat repair because the heat decreases the strength of areas where ultra high strength steel is used. (See the introduction)


b.

Remove the front side panel outer.

K151239C01
1.333,1.167 1.5,1.167 1.5,1.167 2.094,1.771 false 1.167,1.083 1.479,1.24 0.313,0.156 10 false *1 4.104,1.344 4.417,1.5 0.313,0.156 10 false *a 4.802,5.333 5.115,5.49 0.313,0.156 10 false *b
*1 FRONT SIDE PANEL OUTER - -
*a 85 mm (3.35 in.) *b 205 mm (8.07 in.)


K151240

K151550


c.

Roughly cut open the panel so that the adhesive can be reached. Cut through the adhesive with a cut chisel to remove the panel.

HINT:

In cases where the adhesive cannot be removed with a cut chisel, heat the adhesive with an industrial heater gun or gas burner taking care not to cause panel deformation by overheating.


K153058C01
0.167,0.167 0.479,0.323 0.313,0.156 10 false *A
*A for Wagon - -
K108837

Adhesive - -



d.

Remove the front body pillar reinforcement upper and front pillar reinforcement sub-assembly lower.

K151241C01
2.115,1.635 1.833,1.083 1.833,1.083 1.667,1.083 false 2.094,3.469 1.25,4.25 1.25,4.25 1.083,4.25 false 1.479,0.99 1.792,1.146 0.313,0.156 10 false *1 0.917,4.177 1.229,4.333 0.313,0.156 10 false *2
*1 FRONT BODY PILLAR REINFORCEMENT UPPER *2 FRONT PILLAR REINFORCEMENT SUB-ASSEMBLY LOWER




INSTALLATION


Symbol Meaning
K108823

Plug Weld
K108824

Plug Weld
K108825

Plug Weld
K108831

Butt Weld
K108834

Body Sealer

a.

Inspect the fitting of the related parts around the new parts before welding. This affects the appearance of the finish.


b.

Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)


c.

Before temporarily installing the new parts, weld the front body pillar reinforcement upper and front pillar reinforcement sub-assembly lower with the standard number of welding points.

K151242C01
2.917,3.083 3.083,3.083 3.083,3.083 3.302,2.5 false 3.615,0.583 4.083,0.917 4.083,0.917 4.25,0.917 false 4.354,0.844 4.667,1 0.313,0.156 10 false *1 2.719,3 3.031,3.156 0.313,0.156 10 false *2
*1 FRONT BODY PILLAR REINFORCEMENT UPPER *2 FRONT PILLAR REINFORCEMENT SUB-ASSEMBLY LOWER


Follow the welding conditions below when welding ultra high strength steel to assure sufficient weld strength. (When repairing this model)

When welding 2 panels together including 1180 MPa ultra high strength steel.

*a: Plug weld Plug diameter 10 mm (0.39 in.)
Wire type AWS A5.18 ER70S-3
Shield gas Metal active gas

NOTICE:

Be sure to use Metal active gas (Ar 80% + CO2 20%) as the shield gas when plug welding.Sufficient weld strength cannot be assured when using 100% CO2 shield gas.




d.

Apply adhesive (3MTM AutomixTM Panel Bonding Adhesive #8115).

HINT:
·

Do not apply adhesive around the plug welding points.

·

Minimize squeeze out in plug welding areas.



K153058C01
0.167,0.167 0.479,0.323 0.313,0.156 10 false *A
*A for Wagon - -
K108837

Adhesive - -



e.

Weld the front body pillar reinforcement upper and front pillar reinforcement sub-assembly lower to the vehicle side.

K151244C01
2.125,1.604 1.833,0.917 1.833,0.917 1.667,0.917 false 2.167,5.5 2.333,5.5 2.333,5.5 2.594,4.792 false 1.5,0.844 1.813,1 0.313,0.156 10 false *1 1.979,5.427 2.292,5.583 0.313,0.156 10 false *2
*1 FRONT BODY PILLAR REINFORCEMENT UPPER *2 FRONT PILLAR REINFORCEMENT SUB-ASSEMBLY LOWER
*a Ultra High Strength Steel Welding Point - -


Follow the welding conditions below when welding ultra high strength steel to assure sufficient weld strength. (When repairing this model)

When welding 2 panels together including 1180 MPa or 980 MPa ultra high strength steel.

*a: Plug weld Plug diameter 10 mm (0.39 in.)
Wire type AWS A5.18 ER70S-3
Shield gas Metal active gas

NOTICE:

Be sure to use Metal active gas (Ar 80% + CO2 20%) as the shield gas when plug welding.Sufficient weld strength cannot be assured when using 100% CO2 shield gas.




f.

Before installing a new part, apply body sealer.

HINT:

Apply body sealer in an even, continuous bead.


K151243


g.

Weld the front side panel outer to the vehicle side.

K151245C01
2.094,1.76 1.5,0.917 1.5,0.917 1.333,0.917 false 1.146,0.844 1.458,1.042 0.313,0.198 10 false *1
*1 FRONT SIDE PANEL OUTER - -
*a Ultra High Strength Steel Welding Point - -


Follow the welding conditions below when welding ultra high strength steel to assure sufficient weld strength. (When repairing this model)

When welding 3 panels or more together including 1180 MPa or 980 MPa ultra high strength steel. (When plug welding a third panel to 2 panels which are welded under the conditions described above.)

*a: Plug weld Plug diameter Same as the standard method (See the introduction)
Wire type AWS A5.18 ER70S-3
Shield gas Metal active gas

NOTICE:

Be sure to use Metal active gas (Ar 80% + CO2 20%) as the shield gas when plug welding.Sufficient weld strength cannot be assured when using 100% CO2 shield gas.



K151246C01
2.125,1.344 3.333,0.833 3.333,0.833 3.5,0.833 false 3.583,0.75 3.896,0.948 0.313,0.198 10 false *1
*1 NO.6 PILLAR OUTER BRACKET
*a Ultra High Strength Steel Welding Point - -


Follow the welding conditions below when welding ultra high strength steel to assure sufficient weld strength. (When repairing this model)

When welding 3 panels or more together including 1180 MPa or 980 MPa ultra high strength steel. (When plug welding a third panel to 2 panels which are welded under the conditions described above.)

*a: Plug weld Plug diameter Same as the standard method (See the introduction)
Wire type AWS A5.18 ER70S-3
Shield gas Metal active gas

NOTICE:

Be sure to use Metal active gas (Ar 80% + CO2 20%) as the shield gas when plug welding.Sufficient weld strength cannot be assured when using 100% CO2 shield gas.




h.

After welding, apply the foamed sealing material to the corresponding parts. (See the painting/coating)


i.

After welding, apply body sealer to the corresponding parts. (See the painting/coating)


j.

After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.