Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2019.02–2019.06
NM35X0E _58 Vehicle Interior _078578 HEATING / AIR CONDITIONING _0381952 AIR CONDITIONING SYSTEM CO CONTROL F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  CONTROL  AIR CONDITIONING CONTROL  


FUNCTION OF MAIN COMPONENTS


a.

The air conditioning system consists of the following parts:

Control Outline

*1: Models with automatic air conditioning system

*2: Except models with automatic air conditioning system

*3: On models with manual heater system and boost vent system, evaporator fin sensor has been provided, but is not used.

*4: Models with manual rear cooler system

*5: DX grade

*6: GL grade

*7: Models with manual rear heater system

*8: Models with PTC heater

*9: Except models with manual heater system and boost vent system

*10: Models with viscous heater

*11: Models with condenser fan

*12: Models with manual air conditioning system, manual cooler system or manual heater system

*13: DX grade with manual rear cooler system

*14: GL grade with manual rear cooler system

*15: Models with idle up switch

*16: Models with manual air conditioning system or manual cooler system without automatic light control system

*17: Models with automatic light control system

Air Conditioning Amplifier Assembly Transmits and receives data to and from the switches and sensors, and controls the air conditioning system.
Air Conditioning Unit Assembly No. 1 Air Conditioner Damper Servo Sub-assembly*1 Mode Door Switching Servo Motor Controlled by the air conditioning amplifier assembly to move the mode control dampers and switch the registers.
Air Mix Servo Motor Controlled by the air conditioning amplifier assembly to move the air mix control dampers and outlet air temperature..
No. 1 Blower Damper Servo Sub-assembly Fresh/Recirculation Switching Servo Motor Controlled by the air conditioning amplifier assembly to move the fresh/recirculation damper and air inlet mode.
Blower Motor with Fan Sub-assembly
·

Driven according to the target airflow volume calculated by the air conditioning amplifier assembly to blow air toward the cabin and circulate the air inside the cabin.*1

·

Driven according to the blower switch position to blow air toward the cabin and circulate the air inside the cabin.*2


Evaporator Fin Sensor (No. 1 Cooler Thermistor)*3 Detects the temperature of the cool air past the cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
Rear Cooling Unit Assembly*4 Rear Evaporator Fin Sensor (No. 2 Cooler Thermistor) Detects the temperature of the cool air past the cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
Rear Blower Motor with Fan Sub-assembly Driven according to the rear cooler blower switch position to blow air toward the cabin and circulate the air inside the cabin.
Rear Cooler Blower Resistor*5 Changes the resistance value according to operation of the rear blower cooler switch.
Blower Motor Control*6 Controlled by the air conditioning amplifier assembly to control the rear blower motor with fan sub-assembly.
Rear Heater Assembly*7 Rear Heater Blower Motor Sub-assembly Driven according to the rear heater blower switch position to blow air toward the cabin and circulate the air inside the cabin.
Rear Heater Blower Resistor Changes the resistance value according to operation of the rear heater blower switch.
PTC Heater (Quick Heater Assembly)*8 Generates heat according to the current from the PTC heater relay controlled by the air conditioning amplifier assembly to warm the air inside the front air conditioning unit.
Cooler Compressor Assembly*9 Performs suction, compression and discharge of refrigerant gas.
Viscous Heater Assembly with Magnet Clutch*10 This system complements the conventional heater (heater core) when the engine coolant temperature is low, and accelerates the engine warm up by using the viscous power heater unit driven by the engine. As a result, heater performance improvement in cold conditions is successfully achieved.
Blower Assembly with Shroud*11 Operates the blower according to the current from the condenser fan relay controlled by the air conditioning amplifier assembly, blowing air to the cooler condenser assembly and cooling the cooler condenser assembly.
Air Conditioning Control Assembly*1 Allows operation and adjustment of the air conditioning via switches.
Heater Control Knob*2 Outputs mode setting switch and rear window defogger switch position signals to the air conditioning amplifier assembly.
No. 2 Heater Control Knob*2 Outputs blower level setting switch and fresh/recirculation switch position signals to the air conditioning amplifier assembly.
No. 3 Heater Control Knob*12 Outputs temperature setting switch and A/C switch position signals to the air conditioning amplifier assembly.
No. 2 Air Conditioning Control Sub-assembly*13
·

Switches the blower level of the rear cooler system and rear heater system*6 and controls to the rear cooler blower resistor and rear heater blower resistor.*4

·

Switches the blower level of the rear cooler system and rear heater system*6 and outputs signals to the integration control and panel assembly.*5


Integration Control and Panel Sub-assembly*14
·

Outputs rear cooler system blower level switch signals to the air conditioning amplifier assembly.

·

Receives rear cooler system blower level switch signals from the heater control and accessory assembly and outputs them to the air conditioning amplifier assembly.

·

Receives rear heater system blower level switch signals from the heater control and accessory assembly and controls the rear heater blower resistor.*6


Heater Switch Assembly*0 Outputs a power switch position signal and transmits it to the air conditioning amplifier assembly.
Idle Up Switch*15 Outputs an idle up switch position signal and transmits it to the air conditioning amplifier assembly.
Cooler Thermistor (Room Temp. Sensor)*1 Detects the internal temperature inside the cabin and outputs that data to the air conditioning amplifier assembly.
Ambient Temperature Sensor (Thermistor Assembly) Detects the ambient temperature and outputs it to the combination meter assembly.
Air Conditioner Pressure Sensor*9 Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly.
Solar Sensor (Cooler Thermistor)*16 Detects the changes in the amount of solar energy and outputs them to the air conditioning amplifier assembly.
Solar Sensor (Automatic Light Control Sensor)*17 Detects the changes in the amount of solar energy and outputs them to the main body ECU.
Combination Meter Assembly Sends ambient temperature signals to the air conditioning amplifier assembly.
Main Body ECU (Multiplex Network Body ECU) Sends solar energy level difference signals to the air conditioning amplifier assembly.*17
ECM Receives the signals from the engine coolant temperature sensor and transmits them to the air conditioning amplifier assembly.
Central Gateway ECU (Network Gateway ECU) Relays the signal between the CAN communication lines.
DLC3
·

The Global TechStream (GTS) can be connected to read the Diagnostic Trouble Codes (DTCs) of malfunctions.

·

The Global TechStream (GTS) can be connected to change settings as desired by the user.





SYSTEM CONTROL


a.

The automatic air conditioning system uses the following controls:

Control Function
Neural Network Control This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship that is similar to a human brain.
Outlet Air Temperature Control Based on the temperature set by the temperature control switch, the neural network control calculates the outlet air temperature based on the input signals from various sensors.
Blower Control Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors.
Automatically increases the blower level when the defroster is on.
Air Outlet Control Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control based on the input signals from various sensors.
In accordance with the engine coolant temperature, outside air temperature, amount of sunlight, required blower, outlet temperature and vehicle speed conditions, this control automatically switches the blower outlet to FOOT/DEF mode to prevent the windows from becoming fogged when the outside air temperature is low.
Air Inlet Control Automatically controls the air inlet control damper to achieve the calculated outlet air temperature that is required.
Drives the No. 1 blower damper servo sub-assembly (fresh/recirculation damper) in accordance with the operation of the air inlet control switch and moves the dampers to the FRESH or RECIRC position.
PTC Heater Control When the ignition switch is turned ON and the blower motor is turned on, the air conditioning amplifier assembly turns on the PTC heater if the following conditions are met.
·

Engine coolant temperature is below specified temperature.

·

Ambient temperature is below specified temperature.

·

Tentative air mix damper opening angle is above the specified value (MAX HOT).


Compressor Control This control turns off the magnetic clutch of the cooler compressor assembly when the blower motor is turned off at the time the engine coolant temperature is below a predetermined value, an abnormal refrigerant pressure has been input, or the discharge temperature of the evaporator is below a predetermined value.
When the DEF mode switch is turned on, the magnetic clutch relay is activated automatically to engage the cooler compressor assembly. Also, when the blower is turned off, and the front defroster switch is turned on, the blower will turn on in the automatic control condition.
Turns the air conditioning on automatically by pressing the AUTO button when the blower is on and the air conditioning is off.


b.

The manual air conditioning system, manual cooler system, manual heater system or boost vent system uses the following controls:

Control Function

*: Models with PTC heater

PTC Heater Control* When the ignition switch is turned to ON and the blower motor is turned on, the air conditioning amplifier assembly turns on the PTC heater if the following conditions are met.
·

Engine coolant temperature is below specified temperature.

·

Ambient temperature is below specified temperature.

·

Tentative air mix damper opening angle is above the specified value (MAX HOT).




c.

Neural Network Control (Models with Automatic Air Conditioning System)

i.

In the previous automatic air conditioning system, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with a calculation formula that had been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, but extremely uncomfortable in a hot climate. Therefore, as a technique for performing a high level of control, a neural network is used in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly, which performs control to provide enhanced air conditioning comfort.


ii.

The neural network control consists of neurons in an input layer, an intermediate layer, and an output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of this data is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor with fan sub-assembly in accordance with the control volumes that have been calculated by the neural network control.

Y128416E01
2.99,0.073 4.208,0.396 1.219,0.323 10 false Intermediate Layer 3.958,0.385 5.177,0.708 1.219,0.323 10 false Output Layer 2.396,0.385 3.615,0.708 1.219,0.323 10 false Input Layer 4.594,0.74 6.354,1.094 1.76,0.354 10 false Target Output Temperature 1.188,0.74 2.948,1.094 1.76,0.354 10 false Ambient Temperature 1.323,1.406 2.677,1.781 1.354,0.375 10 false Amount of Sunlight 1.333,2.01 2.688,2.385 1.354,0.375 10 false Room Temperature 2.677,3.125 3.177,3.438 0.5,0.313 10 false Control 0.313,4.083 1.448,4.427 1.135,0.344 10 false Input Processing 2.333,3.563 3.531,3.865 1.198,0.302 10 false Neural Networking 2.49,4.104 3.333,4.521 0.844,0.417 10 false Target Outlet Temperature 0.385,5.25 1.198,5.802 0.813,0.552 10 false Temperature Setting 0.375,6.51 1.208,6.823 0.833,0.313 10 false Sensor Input 0.385,7.583 1.219,7.896 0.833,0.313 10 false Switch Input 0.594,8.458 2.698,8.771 2.104,0.313 10 false : Neural network operation range 2.313,4.896 3.5,5.344 1.188,0.448 10 false Amount of Sunlight Correction 2.479,5.698 3.344,6.271 0.865,0.573 10 false Target Airflow Volume 2.51,6.531 3.313,6.823 0.802,0.292 10 false Outlet Mode 2.583,7.281 3.24,7.563 0.656,0.281 10 false Inlet Mode 2.531,7.823 3.375,8.104 0.844,0.281 10 false Compressor 3.969,4.583 5.24,5.052 1.271,0.469 10 false Temperature Control Correction 3.865,5.708 5.365,6.208 1.5,0.5 10 false Various Types of Airflow Volume Corrections 3.906,6.427 5.344,6.938 1.438,0.51 10 false Various Types of Mode Corrections 4.063,7.167 5.135,7.698 1.073,0.531 10 false Various Types of Corrections 5.792,4.094 6.927,4.438 1.135,0.344 10 false Output Correction 5.885,4.635 6.833,5.125 0.948,0.49 10 false Air Mix Control Damper 5.917,5.833 6.813,6.135 0.896,0.302 10 false Blower Motor 5.938,6.438 6.771,6.958 0.833,0.521 10 false Mode Control Damper 5.854,7.146 6.823,7.656 0.969,0.51 10 false Air Inlet Control Damper 5.958,7.875 6.802,8.156 0.844,0.281 10 false Compressor



d.

Fresh Air Introduction while Parking Mode (Models with Automatic Air Conditioning System)

i.

While parking, fresh air introduction mode is automatically selected to enhance ventilation and reduce any odor remaining in the air conditioning unit, minimizing odor during engine start-up.

Timing Chart (Sample)
Y240629E05
1.99,0.635 2.677,0.917 0.688,0.281 10 false Last Mode 3.969,0.177 5.708,0.573 1.74,0.396 10 false Fresh Air Introduction while Parking Mode 6.698,2.604 7.125,3.031 0.427,0.427 10 false Time 2.417,2.615 3.365,3.083 0.948,0.469 10 false Ignition Switch OFF 5.219,2.583 6.479,3.104 1.26,0.521 10 false Ignition Switch ON 1.344,3.333 4.302,3.792 2.958,0.458 10 false When last mode was fresh air mode 1.354,3.677 4.313,4.135 2.958,0.458 10 false When last mode was recirculated air mode 0.958,1.854 1.792,2.302 0.833,0.448 10 false Recirculated Air 1.115,1.292 1.74,1.75 0.625,0.458 10 false Fresh Air 0.229,1.563 1.063,2.01 0.833,0.448 10 false Air Inlet




DIAGNOSIS


a.

In order to make system inspections easier to perform, a diagnosis function is used in consideration of serviceability. The Diagnostic Trouble Codes (DTCs) of malfunctions can be read by connecting the Global TechStream (GTS). For details, refer to the Repair Manual.