Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › 2019.02–2019.06
NM35X0E _58 Vehicle Interior _078578 HEATING / AIR CONDITIONING _0381952 AIR CONDITIONING SYSTEM DE DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DETAILS  COOLER COMPRESSOR  


CONSTRUCTION


a.

A fixed capacity swash plate type 10SRE15C*1 or 10SRE18C*2 compressor is used.


b.

A rotary valve that intakes refrigerant directly into the cylinder is used, achieving a reduction in refrigerant intake loss.


c.

A shaft oil separator that separates compressor oil from the refrigerant is used.

i.

Compressor oil, which has been mixed with the refrigerant and circulated in the air conditioning cycle, is separated by the shaft oil separator built into the shaft and accumulated in the compressor.


ii.

For the shaft oil separator, an oil return passage is located between the cylinder and the lug plate, and refrigerant gas in which a small amount of oil is mixed is sent to the intake chamber. As a result, the oil circulation amount in the air conditioning cycle is reduced.

*1: Models without manual rear cooler system

*2: Models with manual rear cooler system


Y175704C01
4.635,1.604 5.833,1.125 true 4.146,2.063 5.656,2.813 true 1.896,1.833 1.083,1.469 true 3.104,1.604 2.292,0.438 true 2.833,0.406 3.146,1.083 true 3.646,1.219 3.938,0.333 true 2.719,0.208 3.031,0.365 0.313,0.156 10 false *1 2.135,0.26 2.448,0.417 0.313,0.156 10 false *2 0.917,1.313 1.229,1.469 0.313,0.156 10 false *3 5.708,2.74 6.021,2.896 0.313,0.156 10 false *4 3.896,0.125 4.208,0.281 0.313,0.156 10 false *5 5.865,0.99 6.177,1.146 0.313,0.156 10 false *2
*1 Piston *2 Rotary Valve
*3 Shaft *4 Oil Separator
*5 Swash Plate - -




d.

Rotary Valve

i.

The rotary valve has a structure where refrigerant passing through the center of the hollow shaft is taken into the compression areas within the cylinder. The intake of refrigerant occurs when the openings of the shaft and cylinder overlap.

Y147653C01
1.969,0.604 2.76,1.104 true 2.042,2.333 3.76,1.833 true 3.875,3.365 3.698,1.99 true 4.771,3 4.104,2.323 true 5.281,2.469 4.083,1.958 true 4.51,1.771 4.635,0.729 4.635,0.729 3.594,1.563 true 5.042,2.76 3.865,1.958 true 1.813,0.49 2.125,0.646 0.313,0.156 10 false *1 4.76,3.042 5.073,3.198 0.313,0.156 10 false *2 5.313,2.458 5.625,2.615 0.313,0.156 10 false *3 1.865,2.281 2.177,2.438 0.313,0.156 10 false *a 3.854,3.385 4.167,3.542 0.313,0.156 10 false *b 5.073,2.76 5.385,2.917 0.313,0.156 10 false *c 4.594,0.583 4.906,0.74 0.313,0.156 10 false *d
*1 Cylinder *2 Piston
*3 Shaft - -
*a Rotary Valve Intake *b Position where Rotary Valve Intake and Cylinder Intake Passage Align