CONSTRUCTION
The function of the common-rail assembly is to store the fuel that has been pressurized by the supply pump assembly.
The common-rail assembly is provided with a fuel pressure sensor and pressure discharge valve.
The fuel pressure sensor detects the fuel pressure in the common-rail assembly.
The pressure discharge valve regulates the fuel pressure. In the pressure discharge valve, the plunger opens and closes in accordance with the actuation signals from the ECM. As a result, it regulates pressure by releasing excess pressure from the common-rail assembly. In addition, it has a pressure reduction function in case of emergency.
| *1 | Common-rail Assembly | *2 | Fuel Pressure Sensor |
| *3 | Pressure Discharge Valve | - | - |
| *a | To Injector Assembly | *b | From Supply Pump Assembly |
| *c | To Fuel Tank Assembly (Excess Pressure) | - | - |