Home › Engine / Hybrid System › 1GD-FTV (STARTING) › STARTING SYSTEM › 2019.02–2019.06
NM35X0E _51 Engine / Hybrid System _080146 1GD-FTV STARTING _0389541 STARTING SYSTEM GE GENERAL F

1GD-FTV STARTING  STARTING SYSTEM  GENERAL  GENERAL  


OUTLINE


a.

A planetary type starter assembly is used.


b.

An Inrush Current Reduction (ICR) relay, which is built into the planetary type starter assembly, is used. The ICR relay stabilizes the vehicle power source voltage during starter motor operation.*

*: Models with stop and start system



c.

A tandem solenoid type starter assembly is used. This starter uses a structure in which the flow of current is independently supplied to the motor current solenoid and the solenoid used to push out the pinion gear. Due to this, it is possible to restart the engine when the engine has been stopped but is still moving due to inertia, thereby reducing the amount of time to restart the engine during idling stop control.*

*: Models with stop and start system




SPECIFICATION


Models without Stop and Start System
Except Destination Package for Russia and Georgia Destination Package for Russia and Georgia

*1: Length from the mounted area to the rear end of the starter

*2: Viewed from pinion side

Manufacturer DENSO DENSO
Rating Output 2.0 kW 3.0 kW
Rating Voltage 12 V 12 V
Length*1 196.1 mm (7.72 in.) 230.5 mm (9.07 in.)
Weight 3550 g (7.83 lb) 10.6 kg (23.4 lb)
Rotational Direction*2 Clockwise Clockwise

Models with Stop and Start System

*1: Length from the mounted area to the rear end of the starter

*2: Viewed from pinion side

Starter Type Tandem Solenoid
Manufacturer DENSO
Rating Output 2.4 kW
Rating Voltage 12 V
Length*1 217.7 mm (8.57 in.)
Weight 10500 g (23.2 lb)
Rotational Direction*2 Clockwise