When the battery saving control operates, the main body ECU (multiplex network body ECU) controls the operation of the DOME CUT and DOME CUT NO. 2 relay to turn off the interior lights.
Inspect fuses for circuits related to this system before performing the following inspection procedure.
Perform the Active Test according to the display on the GTS.
Click hereVehicle Interior>LIGHTING (INT)>LIGHTING SYSTEM>DATA LIST / ACTIVE TEST
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Relay for Interior Light Auto Cut Function | DOME CUT relay | ON or OFF | When performing this Active Test, turn all the interior lights on.
·
OFF: DOME CUT relay on (interior lights turn on) ·
ON: DOME CUT relay off (interior lights turn off) |
| Tester Display |
|---|
| Relay for Interior Light Auto Cut Function |
All of the interior lights turn off when ON is selected.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
| *A | for LHD | *B | for RHD |
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-23 (DOMR) - A-11 (GND1) | Battery not connected to 3E-1 and A-23 (DOMR) | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-23 (DOMR) - A-11 (GND1) | Battery not connected to 3G-1 and A-23 (DOMR) | 10 kΩ or higher |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3B-19 - Battery negative (-) terminal | Battery positive (+) → 3E-1
Battery negative (-) → A-23 (DOMR) |
11 to 14 V |
| Battery not connected to 3E-1 and A-23 (DOMR) | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3B-19 - Battery negative (-) terminal | Battery positive (+) → 3G-1
Battery negative (-) → A-23 (DOMR) |
11 to 14 V |
| Battery not connected to 3G-1 and A-23 (DOMR) | Below 1 V |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
A
B
C
D