28100
1.INSPECT STARTER ASSEMBLY
As a large electric current passes through the cable during this inspection, a thick cable must be used. Otherwise, the cable may become hot and cause injury.
These tests must be performed within 3 to 5 seconds to avoid burning out the coil.
When replacing the starter assembly, it is necessary to replace the starter relay (ST) and starter relay (ST No. 2).
Mount the starter assembly in a vise between aluminum plates.
Perform a no-load performance test.
| *a | Starter Body |
|
Moves Outward |
Connect the positive (+) lead to terminal SL1.
Connect the negative (-) lead to the starter body and check that the clutch pinion gear moves outward.
Be careful when connecting the leads, as the starter assembly may be damaged if the leads are connecting to the wrong locations.
If the clutch pinion gear does not extend, replace the starter assembly, starter relay (ST) and starter relay (ST No. 2).
| *a | Starter Body |
|
Return Inward |
|
Disconnect |
With the clutch pinion gear in the outward position, disconnect the negative (-) lead and check that the clutch pinion gear returns inward.
If the clutch pinion gear does not return inward, replace the starter assembly, starter relay (ST) and starter relay (ST No. 2).
| *a | Starter Body |
Connect the positive (+) lead to terminal SL2 of the connector and the negative (-) lead to the starter body. Check that a clicking sound is heard from the starter motor.
Be careful when connecting the leads, as the starter assembly may be damaged if the leads are connecting to the wrong locations.
If the result is not as specified, replace the starter assembly, starter relay (ST) and starter relay (ST No. 2).
Connect the battery and an ammeter (AC/DC 400 A probe) to the starter assembly as shown in the illustration.
| *a | Terminal 30 | *b | Starter Body |
| *c | AC/DC 400 A Probe | - | - |
Be careful when connecting the leads, as the starter assembly may be damaged if the leads are connecting to the wrong locations.
Connect the negative (-) battery cable and measure the current after the ammeter (AC/DC 400 A probe) reading has stabilized.
210 A or less at 11 V
When replacing the starter assembly, it is necessary to replace the starter relay (ST) and starter relay (ST No. 2).
If the result is not as specified, replace the starter assembly, starter relay (ST) and starter relay (ST No. 2).
Check the starter clutch.
|
Free |
|
Lock |
Rotate the clutch pinion gear clockwise and check that it turns freely. Try to rotate the clutch pinion gear counterclockwise and check that it locks.
When replacing the starter assembly, it is necessary to replace the starter relay (ST) and starter relay (ST No. 2).
If the result is not as specified, replace the starter assembly, starter relay (ST) and starter relay (ST No. 2).