28300
1.INSPECT STARTER RELAY (ST)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the starter relay (ST).
28300F
2.INSPECT STARTER NO. 2 RELAY (ST NO. 2) (w/ Stop And Start System)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the starter No. 2 relay (ST NO. 2).
28610
3.INSPECT GLOW RELAY (GLOW)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the glow relay (GLOW).