Home › Power Source / Network › 1GD-FTV (BATTERY / CHARGING) › CHARGING SYSTEM
RM35X0E _57 Power Source / Network _078663 1GD-FTV BATTERY / CHARGING _0383346 CHARGING SYSTEM U

1GD-FTV BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


A340466E54
0.531,0.438 0.969,0.677 0.438,0.24 1.74,0.438 2.177,0.677 0.438,0.24 2.844,0.438 3.281,0.677 0.438,0.24 3.885,0.438 4.323,0.677 0.438,0.24 5,0.438 5.438,0.677 0.438,0.24 6.156,0.438 6.594,0.677 0.438,0.24 1.875,0.469 2.188,0.667 0.313,0.198 10 false E6 0.667,0.469 0.979,0.667 0.313,0.198 10 false E5 2.979,0.469 3.292,0.667 0.313,0.198 10 false E7 4.021,0.479 4.333,0.677 0.313,0.198 10 false E8 5.135,0.469 5.448,0.667 0.313,0.198 10 false N2 6.292,0.469 6.604,0.667 0.313,0.198 10 false A2

HINT:

The standard normal voltage and resistance between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage and resistance for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A2-5 (E1) - Body ground W-B - - Ground Always Below 1 Ω
N2-1 (BATT) - A2-5 (E1) L - W-B Battery
(for measuring battery voltage and for ECM memory)
Always 11 to 14 V
E8-7 (LIN) - Body ground P - - LIN communication line Ignition switch off
(while LIN communication stopped)
10 kΩ or higher