Only refill with urea solution (AdBlue) (compliant with ISO 22241-1).
Take care when refilling urea solution (AdBlue) without using SST, as urea solution (AdBlue) may overflow from the refill port.
If urea solution (AdBlue) comes into contact with any painted surfaces on the vehicle, immediately wash the affected areas with water.
If urea solution (AdBlue) is spilled inside the engine compartment, immediately wipe it with a wet cloth.
1.REFILL UREA SOLUTION (AdBlue)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List / Reductant Level.
| Tester Display |
|---|
| Reductant Level |
Inspect the add capacity of the urea solution (AdBlue).
Approximately 13.1 liters (13.8 US qts, 11.5 Imp. qts)
| Reductant Level | Specified Condition |
|---|---|
| 6 | Approximately 6.1 to 13.1 liters (6.4 to 13.8 US qts, 5.4 to 11.5 Imp. qts) |
| 5 | Approximately 4.6 to 6.1 liters (4.9 to 6.4 US qts, 4.0 to 5.4 Imp. qts) |
| 4 | Approximately 3.2 to 4.6 liters (3.4 to 4.9 US qts, 2.8 to 4.0 Imp. qts) |
| 3 | Approximately 1.9 to 3.2 liters (2.0 to 3.4 US qts, 1.7 to 2.8 Imp. qts) |
| 2 | Approximately 0.6 to 1.9 liters (0.6 to 2.0 US qts, 0.5 to 1.7 Imp. qts) |
| 1 | Approximately 0 to 0.6 liters (0 to 0.6 US qts, 0 to 0.5 Imp. qts) |
The level display of the urea solution slightly differs such as the urea solution (AdBlue) decreasing due to driving, or increasing due to refilling.
The remaining amount of urea solution (AdBlue) is the value when the urea tank assembly is parallel to the ground.
Disconnect the GTS from the DLC3.
Remove the urea tank cap assembly.
Set SST to the urea tank filler pipe assembly and refill the urea solution (AdBlue).
For instructions on how to use SST, refer to its instruction manual.
Remove SST from the urea tank filler pipe assembly.
If urea solution (AdBlue) comes into contact with any painted surfaces on the vehicle, immediately wash the affected areas with water.
If urea solution (AdBlue) is spilled inside the engine compartment, immediately wipe it with a wet cloth.
Install the urea tank cap assembly.