1GD-FTV EMISSION CONTROL  UREA PUMP  INSPECTION  


PROCEDURE

Hide 77871A 1.INSPECT UREA PUMP

a.

Inspect the level sensor.

i.
A355507C02
0.552,2.417 0.688,2.417 0.688,2.417 1.219,2.667 true 0.635,3.75 0.719,3.75 0.719,3.75 1.219,3.5 true 1.865,1.469 1.865,1.333 1.865,1.333 2.031,0.969 true 2.094,0.75 2.354,0.25 2.354,0.25 2.521,0.25 true 0.333,2.333 0.583,2.5 0.25,0.167 10 false *b 0.417,3.667 0.667,3.833 0.25,0.167 10 false *c 0.167,0.167 0.417,0.333 0.25,0.167 10 false *a 1.771,1.5 2.104,1.667 0.333,0.167 10 false LV1 2.583,0.167 3,0.333 0.417,0.167 10 false ELV1
*a Component without harness connected
(Urea Pump)
*b Upper
*c Lower


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
14 (LV1) - 6 (ELV1) Float is up 23.37 to 24.47 kΩ
Float is down 1.40 to 1.46 kΩ




b.

Inspect the tank heater.

i.
A355506C04
1.385,1.198 1.719,1.698 1.719,1.698 1.885,1.698 true 0.51,1.688 0.677,1.688 0.677,1.688 0.927,1.188 true 0.135,0.135 0.448,0.333 0.313,0.198 10 false *a 0.24,1.635 0.615,1.802 0.375,0.167 10 false TH+ 1.927,1.625 2.302,1.792 0.375,0.167 10 false TH-
*a Component without harness connected
(Urea Pump)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
9 (TH+) - 11 (TH-) 25°C (77°F) 1.39 to 1.54 kΩ




c.

Inspect the temperature sensor.

i.
A355506C05
1.229,0.969 1.448,0.469 1.448,0.469 1.615,0.469 true 0.885,0.979 0.667,0.5 0.667,0.5 0.5,0.5 true 0.167,0.427 0.521,0.594 0.354,0.167 10 false TUW 1.656,0.396 2.094,0.563 0.438,0.167 10 false ETUW 0.125,0.146 0.438,0.344 0.313,0.198 10 false *a
*a Component without harness connected
(Urea Pump)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (TUW) - 2 (ETUW) 20°C (68°F) 2.47 to 2.56 kΩ
30°C (86°F) 1.69 to 1.75 kΩ




d.

Inspect the pump motor.

i.
A355506C06
2.531,0.969 2.75,0.469 2.75,0.469 2.917,0.469 true 2.198,0.969 1.979,0.49 1.979,0.49 1.813,0.49 true 2.208,1.198 2,1.688 2,1.688 1.833,1.688 true 2.531,1.188 2.802,1.688 2.802,1.688 2.969,1.688 true 2.958,0.385 3.385,0.552 0.427,0.167 10 false PHAB 1.385,0.396 1.865,0.573 0.479,0.177 10 false PHAA 0.115,0.135 0.427,0.333 0.313,0.198 10 false *a 1.385,1.615 1.854,1.781 0.469,0.167 10 false MGND 3.01,1.594 3.417,1.771 0.406,0.177 10 false PHAC
*a Component without harness connected
(Urea Pump)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (PHAA) - 8 (PHAB) 20 to 30°C (68 to 86°F) 0.35 to 0.43 Ω
7 (PHAA) - 16 (PHAC)
8 (PHAB) - 16 (PHAC)
7 (PHAA) - 15 (MGND) Always 10 kΩ or higher
8 (PHAB) - 15 (MGND)
16 (PHAC) - 15 (MGND)


If the result is not as specified, replace the urea pump.