77871A
1.INSPECT UREA PUMP
Inspect the level sensor.
| *a | Component without harness connected
(Urea Pump) |
| *b | Upper |
| *c | Lower |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 14 (LV1) - 6 (ELV1) | Float is up | 23.37 to 24.47 kΩ |
| Float is down | 1.40 to 1.46 kΩ |
Inspect the tank heater.
| *a | Component without harness connected
(Urea Pump) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 9 (TH+) - 11 (TH-) | 25°C (77°F) | 1.39 to 1.54 kΩ |
Inspect the temperature sensor.
| *a | Component without harness connected
(Urea Pump) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (TUW) - 2 (ETUW) | 20°C (68°F) | 2.47 to 2.56 kΩ |
| 30°C (86°F) | 1.69 to 1.75 kΩ |
Inspect the pump motor.
| *a | Component without harness connected
(Urea Pump) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (PHAA) - 8 (PHAB) | 20 to 30°C (68 to 86°F) | 0.35 to 0.43 Ω |
| 7 (PHAA) - 16 (PHAC) | ||
| 8 (PHAB) - 16 (PHAC) | ||
| 7 (PHAA) - 15 (MGND) | Always | 10 kΩ or higher |
| 8 (PHAB) - 15 (MGND) | ||
| 16 (PHAC) - 15 (MGND) |
If the result is not as specified, replace the urea pump.