25860
1.INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
| *a | Component without harness connected
(No. 1 Vacuum Switching Valve Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 33 to 39 Ω |
| 1 - Body ground
2 - Body ground |
20°C (68°F) | 1 MΩ or higher |
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
Check operation of the No. 1 vacuum switching valve assembly.
| *a | Vacuum |
| *b | Air |
| *c | Port E |
| *d | Port F |
| *e | Filter |
When a vacuum of 60 kPa (450 mmHg, 18 in.Hg) is applied to port F, check that air flows from port E to the filter.
| *a | Air |
| *b | Port F |
| *c | Port E |
Apply battery voltage 12 V across terminals 1 and 2.
Check that air flows from port E to port F.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.