22100
1.INSPECT SUPPLY PUMP ASSEMBLY
Inspect the pre-stroke control valve assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 0.42 to 0.52 Ω |
The temperature indicated in "Condition" is the temperature of the pre-stroke control valve.
If the result is not as specified, replace the supply pump assembly.