17111
1.INSPECT INTAKE MANIFOLD (w/ DPF)
Do not adjust the adjusting screw or 2 actuator installation bolts.
Check the operation of the swirl control valve.
Check that the valve is fully closed under normal conditions.
Connect a vacuum pump to the control valve. Check that the valve is fully opened when a negative pressure of 66.7 kPa (500 mmHg, 19.7 in.Hg) is applied.
Leave it for 1 minute and check that the vacuum pump needle does not move.
If the result is not as specified, replace the intake manifold.
2.INSPECT VACUUM SWITCHING VALVE (for Swirl Control Valve)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 33 to 39 Ω |
| 1 - Body ground
2 - Body ground |
20°C (68°F) | 10 kΩ or higher |
If the result is not as specified, replace the vacuum switching valve.
| *a | Port E |
| *b | Filter |
|
Airflow |
Check the operation according to the value(s) in the table below.
Check that air flows from port E to the filter.
If the result is not as specified, replace the vacuum switching valve.
| *a | Port E |
| *b | Port F |
|
Airflow |
Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If the result is not as specified, replace the vacuum switching valve.