The main body ECU (multiplex network body ECU) controls the daytime running lights.
Inspect the bulbs and fuses for circuits related to this system before performing the following procedure.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Daytime Running Light | Daytime running lights | OFF or ON | - |
| Tester Display |
|---|
| Daytime Running Light |
Daytime running lights illuminate.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM (w/o Headlight ECU)>PROBLEM SYMPTOMS TABLE
NG
Remove the No. 1 integration relay.
Click herePower Source / Network>POWER DISTRIBUTION>INTEGRATION RELAY>REMOVAL
Inspect the DRL relay.
Click herePower Source / Network>POWER DISTRIBUTION>INTEGRATION RELAY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the No. 1 integration relay connector.
| *A | for 1GD-FTV |
| *B | for 7GR-FKS |
| *a | Front view of wire harness connector
(to No. 1 Integration Relay) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1H-1 - Body ground | Always | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1I-1 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK (for Bulb Type Daytime Running Light) |
| OK (for LED Type Daytime Running Light) |
| NG |
OK (for Bulb Type Daytime Running Light)
OK (for LED Type Daytime Running Light)
NG
Disconnect the C3 daytime running light socket LH connector.
Disconnect the C1 daytime running light socket RH connector.
Disconnect the 1B No. 1 integration relay connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-9 - C3-1 (B) | Always | Below 1 Ω |
| 1B-9 or C3-1 (B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 1B No. 1 integration relay connector.
Disconnect the 3C instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-10 - 3C-28 | Always | Below 1 Ω |
| 1B-10 or 3C-28 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Remove the instrument panel junction block assembly.
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3C-28 - A-25 (DRL) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
NG
for LHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD:
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Disconnect the B3 clearance light assembly LH connector.
Disconnect the B4 clearance light assembly RH connector.
Disconnect the 1B No. 1 integration relay connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-9 - B3-1 (B) | Always | Below 1 Ω |
| 1B-9 or B3-1 (B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG