a.
Air conditioning amplifier assembly transmits and receives the signals in each ECU via the CAN communication system and LIN communication system. Also, the air conditioning amplifier assembly transmits and receives the damper position, damper operation, sensor status, etc., signals to and from each actuator.
Air Conditioning Amplifier Assembly ←→ Main Body ECU (Multiplex Network Body ECU)
| Receiver
|
Sender
|
Signal
|
Communication Line
|
| Air conditioning amplifier assembly
|
Main body ECU (multiplex network body ECU)
|
Auto dimmer
|
CAN
|
| Destination symbol
|
| Country code 1st, 2nd, 3rd
|
| Steering wheel
|
| Solar data (R)
|
| Solar data (L)
|
| Main body ECU (multiplex network body ECU)
|
Air conditioning amplifier assembly
|
Ambient temperature display
|
CAN
|
Air Conditioning Amplifier Assembly ←→ Combination Meter Assembly
| Receiver
|
Sender
|
Signal
|
Communication Line
|
| Air conditioning amplifier assembly
|
Combination meter assembly
|
Ambient temperature display
|
CAN
|
| Outside temperature sensor data
|
| Vehicle speed (meter to other)
|
| Combination meter assembly
|
Air conditioning amplifier assembly
|
Ambient temperature display
|
CAN
|
| Switch signal of 0 or 0.5 below decimal point of ambient temperature display
|
Air Conditioning Amplifier Assembly ←→ ECM
| Receiver
|
Sender
|
Signal
|
Communication Line
|
| Air conditioning amplifier assembly
|
ECM
|
ECO mode indicator
|
CAN
|
| Engine type information signal 1 - 4
|
| Eco-run flag
|
| Engine r/min data
|
| Water temperature
|
| Alternative field duty value
|
| A/C control cut-off 1, 2 and 4
|
| Number of PTC heater which is permitted (w/ PTC Heater)
|
| PTC heater drive inhibition (w/ PTC Heater)
|
| Viscous heater drive cut-off (w/ Viscous Heater)
|
| Voltage of accessory battery
|
| Compulsory internal air circulation command signal at high water temperature
|
| ECM
|
Air conditioning amplifier assembly
|
Magnet clutch request
|
CAN
|
| A/C idle up request
|
| Heater idle up request
|
| A/C idle up high request (w/ Idle Up Switch)
|
| Charging control inhibit
|
| Prior A/C control request
|
| Acceleration cut inhibit
|
| Viscous heater drive request (w/ Viscous Heater)
|
| PTC heater control request (w/ PTC Heater)
|
| Generator control inhibit
|
| Cooling performance assistance request signal to transmission system
|
| Heating performance assistance request signal to transmission system
|
| Ambient temperature display
|
Air Conditioning Amplifier Assembly ←→ Air Conditioning Control Assembly
| Receiver
|
Sender
|
Signal
|
Communication Line
|
| Air conditioning amplifier assembly
|
Air conditioning control assembly
|
Independent control A/C information
|
LIN
|
| AUTO switch operation
|
| OFF switch operation
|
| A/C switch operation
|
| Blower switch operation
|
| Auto/manual identification information
|
| Air outlet switch operation
|
| Set temperature switch operation
|
| Heater/cooler identification information
|
| Recirculation/fresh switch operation
|
| Air conditioning control assembly
|
Air conditioning amplifier assembly
|
Blower customize display instruction
|
LIN
|
| Entire front panel display instruction
|
| AUTO display instruction
|
| Blower level display instruction
|
| Recirculation display instruction
|
| Air outlet display instruction
|
| Set temperature display instruction
|
| A/C display instruction
|
Air Conditioning Amplifier Assembly ←→ Damper Servo
| Receiver
|
Sender
|
Signal
|
Communication Line
|
| Air conditioning amplifier assembly
|
No. 1 air conditioning radiator damper servo sub-assembly
|
Damper arm position
|
LIN
|
| No. 1 blower damper servo sub-assembly
|
Direct line
|
| No. 1 air conditioning radiator damper servo sub-assembly
|
Air conditioning amplifier assembly
|
LIN
|
| No. 1 blower damper servo sub-assembly
|
Direct line
|
Air Conditioning Amplifier Assembly ←→ Blower Motor, Sensor, Switch etc.
| Receiver
|
Sender
|
Signal
|
Communication Line
|
| Air conditioning amplifier assembly
|
Cooler thermistor (room temperature sensor)
|
Sensor value
|
Direct line
|
| Air conditioner pressure sensor
|
| Compressor with magnet clutch assembly (lock sensor)
|
| No. 1 cooler thermistor
|
| Idle up switch (w/ Idle Up Switch)
|
Idle up switch operation
|
| Heater switch assembly (w/ Viscous Heater)
|
Power heater switch operation
|
| Blower with fan motor sub-assembly
|
Air conditioning amplifier assembly
|
Drive
|
Direct line
|
| FR MGC relay
|
| VISC HTR relay (w/ Viscous Heater)
|
| PTC HTR relay (w/ PTC Heater)
|