Diagnosis condition: None
Malfunction status: Open or short in ambient temperature sensor circuit
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
Malfunction status: Open or short in evaporator temperature sensor circuit
Diagnosis condition: Cooler compressor assembly operating
Malfunction status: Open or short in cooler compressor circuit
Detection time: None (Present malfunction), continuously for 3 seconds or more (Past malfunction)
Diagnosis condition: Ignition switch ON
Malfunction Status: Refrigerant pressure signal malfunction
Detection time: Continuously for 4 seconds or more (Present malfunction)
Malfunction status: Lost communication with integration control and panel assembly
Detection time: Continuously for 10 seconds or more
Diagnosis condition: The amount of refrigerant is judged to be insufficient in normal operation
Malfunction status: When following condition is detected in refrigerant shortage check in normal operation; Amount of refrigerant is insufficient
Detection time: During air conditioning system operation for 10 minutes or more