89463D
1.INSTALL NITROGEN OXIDES SENSOR
Install the nitrogen oxides sensor to the sensor bracket with the 2 nuts, and attach the 2 clamps.
| *a | Torque Wrench Fulcrum Length |
Using SST, install the nitrogen oxides sensor.
Replace with a new part if it is dropped or if it receives a strong impact.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 49.2 N*m (502 kgf*cm, 36 ft.*lbf)
Install the sensor bracket to the vehicle body with the 2 bolts.
Connect the connector to the nitrogen oxides sensor.
Attach the 2 clamps and connect the No. 4 exhaust gas temperature sensor to the sensor bracket.
Connect the connector to the No. 4 exhaust gas temperature sensor.