RM35X0E
_V1
General
_080617
SPECIFICATIONS
_0392097
1GD-FTV EMISSION CONTROL
F
SPECIFICATIONS 1GD-FTV EMISSION CONTROL SERVICE DATA
NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
33 to 39 Ω
|
1 - Body ground
2 - Body ground
|
20°C (68°F)
|
1 MΩ or higher
|
EXHAUST GAS TEMPERATURE SENSOR
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
89.3 to 159.8 kΩ
|
EXHAUST GAS TEMPERATURE SENSOR (w/ Urea SCR System)
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
50°C (122°F)
|
7894 to 12187 Ω
|
EXHAUST FUEL ADDITION INJECTOR
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
7.1 to 7.9 Ω
|
UREA INJECTOR
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
11.6 to 12.4 kΩ
|
UREA PUMP
| Item
|
Tester Connection
|
Condition
|
Specified Condition
|
| Level sensor
|
14 (LV1) - 6 (ELV1)
|
Float is up
|
23.37 to 24.47 kΩ
|
| 14 (LV1) - 6 (ELV1)
|
Float is down
|
1.40 to 1.46 kΩ
|
| Tank heater
|
9 (TH+) - 11 (TH-)
|
25°C (77°F)
|
1.39 to 1.54 kΩ
|
| Temperature sensor
|
1 (TUW) - 2 (ETUW)
|
20°C (68°F)
|
2.47 to 2.56 kΩ
|
| 1 (TUW) - 2 (ETUW)
|
30°C (86°F)
|
1.69 to 1.75 kΩ
|
| Pump motor
|
7 (PHAA) - 8 (PHAB)
|
20 to 30°C (68 to 86°F)
|
0.35 to 0.43 Ω
|
| 7 (PHAA) - 16 (PHAC)
|
20 to 30°C (68 to 86°F)
|
0.35 to 0.43 Ω
|
| 8 (PHAB) - 16 (PHAC)
|
20 to 30°C (68 to 86°F)
|
0.35 to 0.43 Ω
|
| 7 (PHAA) - 15 (MGND)
|
Always
|
10 kΩ or higher
|
| 8 (PHAB) - 15 (MGND)
|
Always
|
10 kΩ or higher
|
| 16 (PHAC) - 15 (MGND)
|
Always
|
10 kΩ or higher
|