Home › General › SPECIFICATIONS › 1GD-FTV STARTING
RM35X0E _V1 General _080617 SPECIFICATIONS _0392537 1GD-FTV STARTING F

SPECIFICATIONS  1GD-FTV STARTING  SERVICE DATA  


GLOW PLUG
Tester Connection Condition Specified Condition
Glow plug terminal - Body ground 20°C (68°F) Approximately 1.0 Ω

STARTER (for 2.0 kW Type)
Starter Standard current 150 A or less at 11.5 V
Starter brush holder assembly Standard length 10.4 mm (0.409 in.)
Minimum length 5.0 mm (0.197 in.)
Starter armature assembly Maximum circle runout 0.05 mm (0.00197 in.)
Standard commutator diameter 29.0 mm (1.14 in.)
Minimum commutator diameter 28.0 mm (1.10 in.)
Standard undercut depth 0.7 mm (0.0276 in.)
Minimum undercut depth 0.4 mm (0.0157 in.)

Item Tester Connection Condition Specified Condition
Starter brush holder assembly A-B
C-D
D-E
Always Below 1 Ω
Magnet starter switch assembly Terminal 50 - Terminal C Always Below 1 Ω
Terminal 50 - Switch body Below 2 Ω
Starter armature assembly Segment - Segment Always Below 1 Ω
Segment - Coil Core 10 kΩ or higher

STARTER (for 3.0 kW Type)
Starter Standard current 220 A or less at 11.5 V
Starter brush holder assembly Standard length 21.0 mm (0.828 in.)
Minimum length 12.0 mm (0.472 in.)
Standard spring load 28 to 37 N (3 to 4 kgf, 6.3 to 8.3 lbf)
Minimum spring load 15 N (2 kgf, 3.4 lbf)
Starter armature assembly Maximum circle runout 0.05 mm (0.00197 in.)
Standard commutator diameter 43.0 mm (1.69 in.)
Minimum commutator diameter 42.0 mm (1.65 in.)
Standard undercut depth 0.7 mm (0.0276 in.)
Minimum undercut depth 0.2 mm (0.0787 in.)

Item Tester Connection Condition Specified Condition
Starter brush holder assembly Positive (+) brush holder - Negative (-) brush holder Always 10 kΩ or higher
Magnet starter switch assembly Terminal 50 - Terminal C Always Below 1 Ω
Terminal 50 - Switch body Below 2 Ω
Starter yoke assembly Terminal C - Brush Always Below 1 Ω
Terminal C - Starter yoke body 10 kΩ or higher
Starter armature assembly Segment - Segment Always Below 1 Ω
Segment - Coil Core 10 kΩ or higher

STARTER (w/ Stop And Start System)
Starter Current criteria 160 A or less at 11 V

IGNITION SWITCH
Tester Connection Condition Specified Condition
Between all terminals LOCK 10 kΩ or higher
6 (ACC) - 7 (AM1) ACC Below 1 Ω
6 (ACC) - 7 (AM1) - 8 (IG1) ON Below 1 Ω
1 (AM2) - 2 (IG2)
5 (ST1) - 7 (AM1) - 8 (IG1) START Below 1 Ω
1 (AM2) - 2 (IG2) - 4 (ST2)

RELAY (STARTER RELAY(ST), STARTER RELAY(ST NO. 2), GLOW RELAY(GLOW))
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω