Home › General › SPECIFICATIONS › 1GD-FTV ENGINE CONTROL
RM35X0E _V1 General _080617 SPECIFICATIONS _0393086 1GD-FTV ENGINE CONTROL F

SPECIFICATIONS  1GD-FTV ENGINE CONTROL  SERVICE DATA  


MASS AIR FLOW METER
Tester Connection Condition Specified Condition
4 (THA) - 2 (E2G) Always 0.47 to 19.3 kΩ

ENGINE COOLANT TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.32 to 2.59 kΩ
80°C (176°F) 0.310 to 0.326 kΩ

INTAKE AIR TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.21 to 2.65 kΩ
60°C (140°F) 0.54 to 0.62 kΩ

MANIFOLD ABSOLUTE PRESSURE SENSOR
Tester Connection Switch Condition Specified Condition
3 (VC) - 1 (E) Ignition switch ON 4.75 to 5.25 V

AIR FUEL RATIO SENSOR
Tester Connection Condition Specified Condition
1 (HA1A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω
3 (A1A+) - 4 (A1A-) Always 10 kΩ or higher

NO. 1 INTEGRATION RELAY (IG2 MAIN RELAY)
Standard Resistance 1D-1 - A-1 Battery voltage not applied to terminals 1D-2 and 1E-4 10 kΩ or higher
Battery voltage applied to terminals 1D-2 and 1E-4 Below 1 Ω

NO. 1 INTEGRATION RELAY (EDU RELAY)
Standard Resistance 1B-1 - 1B-3 Battery voltage not applied to terminals 1B-6 and 1C-4 10 kΩ or higher
Battery voltage applied to terminals 1B-6 and 1C-4 Below 1 Ω

NO. 1 INTEGRATION RELAY (NOX RELAY)
Standard Resistance 1E-3 - A-1 Battery voltage not applied to terminals 1E-1 and 1E-4 10 kΩ or higher
Battery voltage applied to terminals 1E-1 and 1E-4 Below 1 Ω

NO. 1 INTEGRATION RELAY (E/G W/PMP RELAY)
Standard Resistance 1E-10 - A-1 Battery voltage not applied to terminals 1E-4 and 1E-8 10 kΩ or higher
Battery voltage applied to terminals 1E-4 and 1E-8 Below 1 Ω

EFI MAIN RELAY
Standard Resistance 3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω

DCU MAIN RELAY
Standard Resistance 3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω