Home › Vehicle Interior › SEAT › POWER SEAT SWITCH (for Front Seat) › from 2019.06
RM35X0E _58 Vehicle Interior _078601 SEAT _0398433 POWER SEAT SWITCH(for Front Seat) G

SEAT  POWER SEAT SWITCH(for Front Seat)  INSPECTION  


PROCEDURE

Hide 84922 1.INSPECT FRONT POWER SEAT SWITCH (for LHD)

a.
B552179C02
2.344,1.833 1.875,1.24 true 0.458,1.865 0.792,1.438 true 1.25,1.344 0.781,0.563 true 2.292,3.281 2.927,2.719 true 2.333,3.51 2.844,4.01 true 1.927,3.25 2.302,2.51 true 1.438,4.198 1.542,3.542 true 1.344,3.25 1.063,2.521 true 1.135,3.26 0.583,2.75 true 0.854,4.125 1.333,3.552 true 2.01,4.229 1.906,3.542 true 0.625,3.917 1.104,3.531 true 2.406,4.104 2.115,3.552 true 0.354,1.844 0.667,2 0.313,0.156 10 false *a 0.625,0.406 0.938,0.563 0.313,0.156 10 false *b 2.385,1.75 2.698,1.906 0.313,0.156 10 false *c 0.042,2.031 0.354,2.188 0.313,0.156 10 false *d 0.885,2.333 1.5,2.531 0.615,0.198 10 false SLDF 2.781,2.521 3.396,2.719 0.615,0.198 10 false SLDR 0.531,4.167 1.146,4.365 0.615,0.198 10 false FDWN 2.375,4.135 2.688,4.365 0.313,0.229 10 false FUP 0.365,2.573 0.979,2.771 0.615,0.198 10 false RCLF 2.25,2.271 2.802,2.469 0.552,0.198 10 false RCLR 1.854,4.26 2.25,4.458 0.396,0.198 10 false RUP 2.844,4.021 3.167,4.167 0.323,0.146 10 false B 0.469,3.865 0.792,4.01 0.323,0.146 10 false E 1.146,4.229 1.76,4.427 0.615,0.198 10 false RDWN
*a Slide and Front Vertical Switch
*b Slide and Lifter Switch
*c Reclining Switch
*d Component without harness connected
(Front Power Seat Switch)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Slide Switch:
Tester Connection Switch Condition Specified Condition
4 (SLDF) - 6 (B) Front position Below 1 Ω
1 (SLDR) - 12 (E)
4 (SLDF) - 12 (E) Neutral Below 1 Ω
1 (SLDR) - 12 (E)
4 (SLDF) - 12 (E) Rear position Below 1 Ω
1 (SLDR) - 6 (B)

Front Vertical Switch:
Tester Connection Switch Condition Specified Condition
7 (FUP) - 6 (B) Up position Below 1 Ω
11 (FDWN) - 12 (E)
7 (FUP) - 12 (E) Neutral Below 1 Ω
11 (FDWN) - 12 (E)
7 (FUP) - 12 (E) Down position Below 1 Ω
11 (FDWN) - 6 (B)

Lifter Switch:
Tester Connection Switch Condition Specified Condition
8 (RUP) - 6 (B) Up position Below 1 Ω
10 (RDWN) - 12 (E)
8 (RUP) - 12 (E) Neutral Below 1 Ω
10 (RDWN) - 12 (E)
8 (RUP) - 12 (E) Down position Below 1 Ω
10 (RDWN) - 6 (B)

Reclining Switch:
Tester Connection Switch Condition Specified Condition
5 (RCLF) - 6 (B) Front position Below 1 Ω
3 (RCLR) - 12 (E)
5 (RCLF) - 12 (E) Neutral Below 1 Ω
3 (RCLR) - 12 (E)
5 (RCLF) - 12 (E) Rear position Below 1 Ω
3 (RCLR) - 6 (B)


If the result is not as specified, replace the front power seat switch.


Hide 84922 2.INSPECT FRONT POWER SEAT SWITCH (for RHD)

a.
B552180C01
2.042,1.792 1.656,1.26 true 2.979,1.823 2.677,1.448 true 2.24,1.302 2.635,0.5 true 2.333,3.292 3.073,2.875 true 2.083,3.26 2.781,2.583 true 1.917,3.531 2.031,4.104 true 1.125,3.531 0.521,3.875 true 1.917,3.25 2.229,2.469 true 1.104,3.271 0.375,2.854 true 1.354,3.531 0.865,4.042 true 2.594,4.083 2.094,3.521 true 1.313,4.156 1.531,3.552 true 2.823,3.958 2.292,3.51 true 2.948,1.875 3.26,2.031 0.313,0.156 10 false *a 2.583,0.302 2.896,0.458 0.313,0.156 10 false *b 2.042,1.854 2.354,2.01 0.313,0.156 10 false *c 0.042,2.031 0.354,2.188 0.313,0.156 10 false *d 2.927,2.667 3.427,2.844 0.5,0.177 10 false RCLF 2.656,2.344 3.271,2.542 0.615,0.198 10 false SLDF 0.188,2.667 0.802,2.865 0.615,0.198 10 false SLDR 2.531,4.156 3.146,4.354 0.615,0.198 10 false FDWN 0.688,4.063 1.063,4.24 0.375,0.177 10 false FUP 2.063,2.292 2.677,2.49 0.615,0.198 10 false RCLR 1.865,4.156 2.406,4.344 0.542,0.188 10 false RDWN 0.396,3.813 0.719,3.958 0.323,0.146 10 false B 1.167,4.167 1.552,4.313 0.385,0.146 10 false RUP 2.917,3.927 3.24,4.073 0.323,0.146 10 false E
*a Slide and Front Vertical Switch
*b Slide and Lifter Switch
*c Reclining Switch
*d Component without harness connected
(Front Power Seat Switch)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Slide Switch:
Tester Connection Switch Condition Specified Condition
2 (SLDF) - 12 (B) Front position Below 1 Ω
5 (SLDR) - 6 (E)
2 (SLDF) - 6 (E) Neutral Below 1 Ω
5 (SLDR) - 6 (E)
2 (SLDF) - 6 (E) Rear position Below 1 Ω
5 (SLDR) - 12 (B)

Front Vertical Switch:
Tester Connection Switch Condition Specified Condition
11 (FUP) - 12 (B) Up position Below 1 Ω
7 (FDWN) - 6 (E)
11 (FUP) - 6 (E) Neutral Below 1 Ω
7 (FDWN) - 6 (E)
11 (FUP) - 6 (E) Down position Below 1 Ω
7 (FDWN) - 12 (B)

Lifter Switch:
Tester Connection Switch Condition Specified Condition
10 (RUP) - 12 (B) Up position Below 1 Ω
8 (RDWN) - 6 (E)
10 (RUP) - 6 (E) Neutral Below 1 Ω
8 (RDWN) - 6 (E)
10 (RUP) - 6 (E) Down position Below 1 Ω
8 (RDWN) - 12 (B)

Reclining Switch:
Tester Connection Switch Condition Specified Condition
1 (RCLF) - 12 (B) Front position Below 1 Ω
3 (RCLR) - 6 (E)
1 (RCLF) - 6 (E) Neutral Below 1 Ω
3 (RCLR) - 6 (E)
1 (RCLF) - 6 (E) Rear position Below 1 Ω
3 (RCLR) - 12 (B)


If the result is not as specified, replace the front power seat switch.