The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the generator assembly removal/installation are shown below.
When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is operated normally
1. PRECAUTION
After turning the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
11209
3.REMOVE V-BANK COVER SUB-ASSEMBLY (w/ Cover)
16361A
4.REMOVE FAN AND GENERATOR V BELT
16604
5.REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY
Remove the bolt and No. 2 idler pulley sub-assembly.
17125
6.REMOVE NO. 1 SURGE TANK STAY
27020
7.REMOVE GENERATOR ASSEMBLY
Disconnect the generator connector from the generator assembly.
Remove the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Remove the bolt and disconnect the wire harness from the generator assembly.
Detach the wire harness clamp from the generator bracket.
Remove the bolt and disconnect the generator bracket from the cylinder block.
Remove the 2 bolts and generator assembly.
Remove the bolt and generator bracket from the generator assembly.