Home › General › SPECIFICATIONS › 1GD-FTV INTAKE / EXHAUST › from 2020.05
RM35X0E _V1 General _080617 SPECIFICATIONS _0392856 1GD-FTV INTAKE / EXHAUST F

SPECIFICATIONS  1GD-FTV INTAKE / EXHAUST  SERVICE DATA  


INTAKE SYSTEM
Turbocharging pressure Standard pressure (Gauge Pressure) 11.4 to 47.2 kPa (0.1 to 0.5 kgf/cm2, 1.7 to 6.8 psi)

EXHAUST MANIFOLD W/ TURBOCHARGER
Axial play of turbine shaft Standard 0.11 mm (0.00433 in.)
Turbocharger nozzle vane control actuator E41-1 (M-) - E41-2 (M+) Condition 20°C (68°F) 1 to 100 Ω

EXHAUST PIPE
Compression spring Minimum length 40.2 mm (1.58 in.)

RADIATOR (for Water Cooled Type Intercooler)
Item Condition Specified Condition
Reserve tank cap (for Intercooler) Standard pressure
(for brand-new cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum pressure
(for used cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)