Only Driver Door LOCK / UNLOCK Functions do not Operate
Circuit diagnosis · Vehicles built May 2007 – Jul 2008
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
The main body ECU (instrument panel junction block) receives lock/unlock switch signals and activates the door lock motor according to these signals.WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. INSPECT FRONT DOOR LOCK ASSEMBLY |
 |
Remove the front driver side door lock assembly (Click here).
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
|
Measurement Condition
|
Door Lock Condition
|
Specified Condition
|
7 - 8
|
Battery positive (+) → Terminal 4 Battery negative (-) → Terminal 1
|
Locked
|
10 kΩ or higher
|
7 - 8
|
Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 4
|
Unlocked
|
Below 1 Ω
|
|
NG |
 |
|
|
|
| OK |
|
 |
|
| 2. CHECK HARNESS AND CONNECTOR (FRONT DOOR LOCK MOTOR CIRCUIT) |
 |
for LHD:
Disconnect the instrument panel junction block connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
H6-1 (UL) - 1J-2
|
Always
|
Below 1 Ω
|
H6-4 (L) - 1K-2
|
Always
|
Below 1 Ω
|
H6-1 (UL) - Body ground
|
Always
|
10 kΩ or higher
|
H6-4 (L) - Body ground
|
Always
|
10 kΩ or higher
|
for RHD:
Disconnect the main body ECU (instrument panel junction block) connector.
Disconnect the instrument panel junction block connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
G8-1 (UL) - D7-5 (ACTD)
|
Always
|
Below 1 Ω
|
G8-4 (L) - 1J-1
|
Always
|
Below 1 Ω
|
G8-1 (UL) - Body ground
|
Always
|
10 kΩ or higher
|
G8-4 (L) - Body ground
|
Always
|
10 kΩ or higher
|
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
| OK |
|
 |
|
| 3. CHECK HARNESS AND CONNECTOR (DOOR UNLOCK DETECTION SWITCH CIRCUIT) |
 |
for LHD:
- Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
H6-8 (LSSR) - D7-9 (LSWD)
|
Always
|
Below 1 Ω
|
H6-8 (LSSR) - Body ground
|
Always
|
10 kΩ or higher
|
H6-7 (E) - Body ground
|
Always
|
Below 1 Ω
|
for RHD:
- Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
G8-7 (LSSR) - D7-9 (LSWD)
|
Always
|
Below 1 Ω
|
G8-7 (LSSR) - Body ground
|
Always
|
10 kΩ or higher
|
G8-8 (E) - Body ground
|
Always
|
Below 1 Ω
|
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
| OK |
|
 |
|
| REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK) |
|