ON-VEHICLE INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT REFRIGERANT VOLUME |
Check the sight glass on the air conditioning tube and accessory.

Prepare the vehicle according to the chart below.
Item
Condition
Vehicle door
Fully open
Temperature setting
MAX COOL
Blower speed
HI
A/C
ON
Compare the sight glass to the following chart.
*: Bubbles in the sight glass with the vehicle's interior temperature above 35°C (95°F) can be considered normal if cooling is sufficient.Item
Symptom
Amount of refrigerant
Corrective Actions
1
Bubbles exist
Insufficient*
- Check for gas leakage and repair if necessary
- Recharge with proper amount of refrigerant
2
No bubbles exist (DTC 76 is output)
Empty, insufficient, or excessive
Refer to 3 and 4
3
No temperature difference between compressor inlet and outlet
Empty or nearly empty
- Check for gas leakage and repair if necessary
- Evacuate the AC system and recharge with proper amount of refrigerant
4
Considerable temperature difference between compressor inlet and outlet
Proper or excessive
Refer to 5 and 6
5
Immediately after air conditioning is turned off, refrigerant remains clear
Excessive
- Recover refrigerant
- Evacuate the AC system and recharge with proper amount of refrigerant
6
Immediately after air conditioning is turned off, refrigerant foams and then becomes clear
Proper
-
- Check for gas leakage and repair if necessary
| INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
- HINT:
- This is a method where a manifold gauge set is used to help locate the problem.
Read the manifold gauge pressure when the following conditions are met:
Test conditions:- Temperature at the air inlet with the switch set at RECIRC is 30 to 35°C (86 to 95°F).
- The engine is running at 1500 rpm.
- The blower speed control switch position is at "HI".
- The temperature control dial position is at "COOL".
- The A/C switch is on.
- Doors are fully open.
- The ignition switch is in a position that enables the A/C compressor to run.
Normally functioning refrigeration system

Gauge reading Pressure side
Refrigerant volume
Low
0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 21.3 to 35.5 psi)
High
1.37 to 1.57 MPa (14 to 16 kgf/cm2, 199.1 to 227.5 psi)
Moisture is present in the refrigeration system.


Symptom
Probable Cause
Diagnosis
Corrective Actions
During operation, pressure on low pressure side cycles between normal and vacuum
- Moisture in the AC system will freeze at the expansion valve orifice, causing the refrigeration cycle to temporarily stop
- After the system stops, and warms up again, the ice will melt and normal operation will be temporarily restored
- Cooler dryer (integrated into condenser tank) in oversaturated state
- Moisture in refrigeration system freezes at expansion valve orifice and blocks circulation of refrigerant
- Replace cooler dryer
- Remove moisture in system by repeatedly evacuating air
- Supply a proper amount of new refrigerant
- Moisture in the AC system will freeze at the expansion valve orifice, causing the refrigeration cycle to temporarily stop
Insufficient cooling


Symptom
Probable Cause
Diagnosis
Corrective Actions
- Pressure is low on both low and high pressure sides
- Bubbles are seen through sight glass continuously
- Insufficient cooling performance
Gas leakage from the refrigeration system
- Insufficient refrigerant
- Refrigerant leaking
- Check for gas leaks and repair if necessary
- Supply a proper amount of new refrigerant
- If the gauge indicates a pressure of close to 0, then it will be necessary to evacuate the system after repairing the leak
- Pressure is low on both low and high pressure sides
Poor circulation of refrigerant


Symptom
Probable Cause
Diagnosis
Corrective Actions
- Pressure is low on both low and high pressure sides
- Frost exists on pipe from condenser to unit
Refrigerant flow is obstructed by dirt inside the pipes of the condenser core
Receiver is clogged
Replace condenser
- Pressure is low on both low and high pressure sides
Refrigerant does not circulate.


Symptom
Probable Cause
Diagnosis
Corrective Actions
- Vacuum is indicated on low pressure side and very low pressure is indicated on high pressure side
- Frost or condensation is seen on piping on both sides of receiver/drier or expansion valve
- Refrigerant flow is obstructed by moisture or dirt in refrigeration system
- Refrigerant flow is disrupted by gas leaking internally through the expansion valve
Refrigerant does not circulate
- Check expansion valve
- Replace expansion valve
- Replace condenser
- Evacuate air and supply a proper amount of new refrigerant
- For internal gas leak at expansion valve, replace expansion valve
- Vacuum is indicated on low pressure side and very low pressure is indicated on high pressure side
Refrigerant is overcharged or cooling effectiveness of condenser is insufficient.


Symptom
Probable Cause
Diagnosis
Corrective Actions
- Pressure is too high on both low and high pressure sides
- No air bubbles are seen through sight glass even when engine rpm lowers
- Unable to develop sufficient performance due to excessive use of refrigeration system
- Cooling effectiveness of condenser is insufficient
- Excessive refrigerant in cycle → excessive refrigerant was added during recharging
- Condenser cooling effectiveness is insufficient → condenser fins are clogged at cooling fan
- Clean condenser
- Check the operation of the condenser cooling fan
- If 1 and 2 are normal state, check the amount of refrigerant and supply a proper amount of refrigerant
- Pressure is too high on both low and high pressure sides
Air is present in the refrigeration system.


Symptom
Probable Cause
Diagnosis
Corrective Actions
- Pressure is too high on both low and high pressure sides
- The low pressure piping is too hot to touch
- Bubbles can be seen through sight glass
Air in system
- Air present in refrigeration system
- Insufficient vacuum purging
- Check compressor oil to see if it is dirty or insufficient
- Evacuate the system and recharge it with new or purified refrigerant
- Pressure is too high on both low and high pressure sides
Expansion valve malfunction


Symptom
Probable Cause
Diagnosis
Corrective Actions
- Pressure is too high on both low and high pressure sides
- Frost or a large amount of condensation on piping on low pressure side
Expansion valve may be stuck
- Excessive refrigerant in low pressure piping
- Expansion valve opened too wide
Check expansion valve
- Pressure is too high on both low and high pressure sides
Insufficient compressor compression


Gauge readings (Reference)Symptom
Probable Cause
Diagnosis
Corrective Actions
- Pressure is too high on both low and high pressure sides
- Pressure is too low on high pressure side
Internal leak in compressor
- Low compression
- Leak from a damaged valve, or parts may be broken
Replace compressor


- Pressure is too high on both low and high pressure sides
- Temperature at the air inlet with the switch set at RECIRC is 30 to 35°C (86 to 95°F).
