B1244 Light Sensor Circuit Malfunction
Diagnostic trouble codes · Vehicles built from May 2007
DESCRIPTION
The automatic light control sensor detects ambient light, converts it into an electrical signal, and outputs it to the main body ECU. The main body ECU turns on or off the headlights and taillights according to the signal.| DTC No. |
DTC Detecting Condition |
Trouble Area |
| B1244 |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the intelligent tester on.
Select the following menu items: Body Electrical / Main Body / Data List.
Read the display on the intelligent tester.
Main Body: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Illumination Rate
Illumination rate information / 0 ms to 99.99 ms
Value is output according to ambient light levels
-
- OK:
- Normal condition listed above is displayed.
|
|
||||
| OK | ||
| ||
| 2. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR) |
Disconnect the F1 automatic light control sensor connector.

Disconnect the D6 main body ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
D6-18 (CLTE) - F1-3 (CLTE)
Always
Below 1 Ω
D6-19 (CLTS) - F1-5 (CLTS)
Always
Below 1 Ω
D6-20 (CLTB) - F1-6 (CLTB)
Always
Below 1 Ω
D6-18 (CLTE) - Body ground
Always
10 kΩ or higher
D6-19 (CLTS) - Body ground
Always
10 kΩ or higher
D6-20 (CLTB) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 3. INSPECT MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY ) |
Reconnect the main body ECU connector.
Measure the voltage and resistance according to the value(s) in the table below.


- Standard voltage:
Tester Connection
Condition
Specified Condition
D6-20 (CLTB) - D6-18 (CLTE)
Ignition switch off
Below 1 V
Ignition switch on (IG)
11 to 14 V
- Standard resistance:
Tester Connection
Condition
Specified Condition
D6-18 (CLTE) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 4. INSPECT AUTOMATIC LIGHT CONTROL SENSOR |
Reconnect the automatic light control sensor connector.

Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.

- OK:
Tester Connection
Tool Setting
Condition
Specified Condition
F1-3 (CLTE) - F1-5 (CLTS)
5 V/DIV., 5 ms./DIV.
Ignition switch on (IG), light control switch in AUTO
Correct waveform is as shown
- HINT:
- If the ambient light becomes brighter, width A becomes narrower.
|
|
||||
| OK | ||
| ||