2007-2013 Highlander Kluger · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from May 2007


INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
  1. Resistance inspection:

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      6.9 to 7.9 Ω

      If the result is not as specified, replace the camshaft timing oil control valve assembly.

  1. A164451E01
    Movement inspection:

    1. Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 2, and check the movement of the valve.

      NOTICE:
      Confirm that the valve moves freely and does not stick in any position.

      If the result is not as specified, replace the camshaft timing oil control valve assembly.

      HINT:
      Accumulation of foreign objects causes subtle pressure leaks. The subtle pressure leaks will cause the cam to advance, and this will cause a DTC to be set.

← REMOVAL (from Aug 2013)INSTALLATION (May 2007 – Jul 2008) →